intigrity check of sieve in pharmaceutical.calibration of new sieve. distruction of sieve in pharma
Просмотров 3,3 тыс.2 года назад
indent of new sieve raise the requisition note to purchase department with required specifications for ordering of new sieve receipt the new sieve from the manufacturer and check the quality of sieve as per delivered challen receiving the sieve record the entry in format after then stored the sieve cleaning of new sieve as per sop and affixed the cleaned lable with polybag and kept in suitable ...
sieve separation,sieve inigrity test,types of sieve,what is sieve number,pharma industry use sieve
Просмотров 8342 года назад
The use of a sieve gets rid of oversized contamination to ensure that ingredients and finished products are quality assured during production, different type of sieve use in pharma industry construction of wire stainless steel 316 and brass or bronze four type of sieve use in pharma Woven wire sieve Bolting cloth sieve Bars sieve Punch plating sieve woven wire mesh sieves are the most widely us...
what is rtpcr test,RT-PCR test live hindi ,rtpcr me CT value kya hai,rtpcr test report,
Просмотров 2482 года назад
Along with laboratory testing, chest CT scans may be helpful to diagnose COVID-19 in individuals with a high clinical suspicion of infection. COVID-19 affects different people in different ways. Most infected people will develop mild to moderate illness and recover without hospitalization. Most common symptoms: fever cough tiredness loss of taste or smell Less common symptoms: sore throat heada...
what is OOS,OOT.what is 21 CFR 11.what is SISPQ.what is out of specification.what is out of trend
Просмотров 4692 года назад
out of specification means drugs assay out of limit its means when the drugs perform the assay in QC lab the drugs goes to out of limit.if the specification of drugs is 90 to 110% assay but the asaay of drugs 89% during the analysis it means drugs assay fail and drugs goes to out of limit this problem more in qc . out of trend means the drugs goes out the limit for cmperesion to previous batche...
branded and genric drugs, genric and branded difference branded and genric medicine,branded drugs
Просмотров 3442 года назад
आज भारत सरकार जेनरिक दवाई पर बहुत जोर दे रही है इसका एक कारण ये है कि जेनरिक दवाई का इफेक्ट उतना ही है जितना की ब्रांडेड दवाई का ब्रांडेड ड्रग्स अपने आप में बहुत है हाई क्वालिटी की दवाई है और इफेक्टिव तो बहुत ही ज्यादा है इस दवाई को मार्केट में लाने के लिए किसी भी कम्पनी को 10 से 12 साल लग जाते है इसलिए इस दवाई की कॉस्ट बहुत ज्यादा होती है ये दवाई मार्केट में अलग ही होगी इस दवाई को वो कम्पनी 20...
what is paracetamol?paracetamol tablet ip 500mg ,650mg.paracetamol paidaitric oral suspension ip.
Просмотров 3792 года назад
paracetamol एक महत्वूर्ण drugs हर जिसके बारे में जानकारी होनी बहुत आवश्यक है क्योंकि कोई भी व्यक्ति जो para के बारे में थोड़ा जनता हो या जो ना जानता हो उसके लिए हमने इस वीडियो में सारी nformation दी है para NSAIDS drugs है जो मुख्यत भुखार में काम आती है और दर्द में भी काम आती है para को बिना doctors के सलाह के बगैर नहीं लेना चाहिए क्योंकि para nausia उल्टी और पेट दर्द करता है यदि ज्यादा मात्रा ...
what is roughness of tablet coating ,logo bridging,what is orange peel,types of coating defects.
Просмотров 1,1 тыс.2 года назад
ROUGHNESS means when the coating solution spray in tablet bed but some droplets of tablet before drying so thats cough roughness cause of toughness 1 high dgree of automization 2 high drying rate 3 nozzles to bed distance in close if the roughness is more its means excissive toughness also known as ORANGE PEEL due to the improper spreading of coating solution in tablet before drying cause of or...
SCADA in hindi,SCADA kya hai pharma interview questions and answer PLC,classification of clean room,
Просмотров 5952 года назад
pharma interview में पूछे जाने वाले question जैसे SCADA क्या है PLC क्या होती है इसका क्या काम है LOD and water content में क्या अंतर है SCADA मींस supervisor control and data aqesation यह एक ग्राफिक होता है या किसी भी सिस्टम का सोफवेयर scada है programible logic control यह एक हार्डवेयर है और ये प्रोसेस को कन्ट्रोल करता है LOD means loss on drying loss of water as well as volatile oil वाटर कंटे...
TABLET DEFECTS of coating TWINNING AND MOTTLING (COLOUR VERIATION ) , twinning and mottling क्या है
Просмотров 2152 года назад
twnning और mottling एक प्रकार का coating डिफेक्ट है। जो कि coating process के दौरान आती है mottling को ही colour veraition कहते है जो कि प्रोसेस formilaltion और मशीन से आती है mottling जब समान रूप से टैबलेट के उपर colour फिलता नहीं है तो जिसके कारण डार्क वा लाइट घबे पड़ते है इस प्रकार के डिफेक्ट्स को colour veriation या mottling कहा जाता है mottling के आने के कहीं कारण होते है सबसे पहला करना यद...
what is differential pressure gauge ? .differential pressure in phama.differential pressure gauge.
Просмотров 5 тыс.2 года назад
differential pressure means difference between production area and its surrounding mostly dp maintain by the HVAC system dp measure by the pressure gauge and the unit of pressure is pascal as well as mmwc dp gernelly use to avoid cross cantamination two type of pressure negative pressure positive pressure positive pressure means inside the higher pressure and outside low pressure and the air pa...
lamination in tablets,double impression tablet detects,double imprssion of tablets lamination tablet
Просмотров 3172 года назад
Lamination is the one of the most detects observed during the compression generally thats type of detects occour during compression due to the air entrapment in granules . Lamination mostly separate of two or more layer horizontally from the main body of the tablets so cause lamination problem .This type of problem occurs other ways waxy and oil material in granules and as well as machine relat...
tablets defects cracking,what is chipping, tablets में cracking and chipping कैसे आती है
Просмотров 1212 года назад
full details about cracking and chipping during the manufacturing.
what is sticking and picking?how different sticking and picking.tablet detects sticking and picking
Просмотров 2132 года назад
full detail about tablet defect stockings and picking
defects of tablets.capping of tablets defects of tablet in hindi, manufacturing defects of tablets .
Просмотров 3612 года назад
defects of tablets.capping of tablets defects of tablet in hindi, manufacturing defects of tablets .
die and punch tooling different between B and D tooling punch and dies dies and punch क्या होते है
Просмотров 1,1 тыс.2 года назад
die and punch tooling different between B and D tooling punch and dies dies and punch क्या होते है