How to pass electrical inspection
Here’s a quick tutorial on how to wire your home to pass your electrical rough-in inspection, especially including some of the “surprising” code requirements.
Просмотров: 11 842

Видео

How to pass plumbing inspection
Просмотров 1,6 тыс.Год назад
Here is a short tutorial on how to plumb your home, especially including some of the (surprising) code requirements.
Radioactive iodine treatment 10 28 09
Просмотров 20Год назад
In May of 2009, I found out I have papillary thyroid cancer. On September 3, 2009, my thyroid was removed. I had RAI in October to kill the rest of the thyroid cells. It was so weird to purposely make myself radioactive.
Before my radioactive iodine treatment 10 28 09
Просмотров 3Год назад
Before my radioactive iodine treatment 10 28 09
Pastor Dave's FREE zer Pops
Просмотров 5Год назад
Pastor Dave's FREE zer Pops
Flash Rescues Citizen
Просмотров 105 лет назад
Eli does Flash
Not for a Moment
Просмотров 87 лет назад
Sung by Lauren Rieke Guitar by Luke Rieke At Avalon Hills Bible Church
Special music for offering
Просмотров 68 лет назад
Just for the Ritchies
Believe
Просмотров 28 лет назад
Christmas Eve - Amy Flood and Ben Puckett
Not For A Moment
Просмотров 12510 лет назад
sung by Lauren Rieke at Avalon Hills Bible Church on September 29, 2013 guitar playing by Luke Rieke
The Big House Tour
Просмотров 13410 лет назад
Take a tour and decide how you would decorate this space. Go to The Pastor's Wife at www.teresarieke.com to see the before and after of our remodeling project.
Jeremy Tyler's Wedding Recession
Просмотров 28211 лет назад
Jeremy Tyler's Wedding Recession
Micah's first ride on a motorcycle
Просмотров 6711 лет назад
This is to say "hi" to his daddy, Josh! This is the first time he was not afraid to ride with Pappa.
Glory
Просмотров 7611 лет назад
Glory
Mighty is the Power of the Cross
Просмотров 11311 лет назад
Mighty is the Power of the Cross
It is Well With My Soul
Просмотров 33311 лет назад
It is Well With My Soul
You Are Good
Просмотров 21811 лет назад
You Are Good
Tis So Sweet to Trust in Jesus
Просмотров 69711 лет назад
Tis So Sweet to Trust in Jesus
Hurricane Sandy
Просмотров 26311 лет назад
Hurricane Sandy
What Have I Done Lord Jesus
Просмотров 8511 лет назад
What Have I Done Lord Jesus
Well Done song
Просмотров 59711 лет назад
Well Done song
Well Done
Просмотров 1111 лет назад
Well Done
Greek Festival dancing, May '12
Просмотров 12212 лет назад
Greek Festival dancing, May '12

Комментарии

  • @dustina6261
    @dustina6261 3 месяца назад

    You 1000% can put a t on its back for venting purposes only. Your y is not only unnecessary but backwards anyway lol. Also can’t use a combi fitting on the vertical to horizontal for a trap arm, that’s the same as a y and 45 fitting and puts the connection drain below the trap weir. You really should not give a demonstration video if you are uneducated in the topic you are trying to educate on. Blind leading the blind with this video

  • @mattimus8250
    @mattimus8250 7 месяцев назад

    Here’s a good way to pass an electrical inspection. Call an electrician.

    • @tractorsold1
      @tractorsold1 6 месяцев назад

      Didn't work for the contractor who built our house. Day before closing, it failed electrical inspection because there was no ground at some of the outlets.

    • @mattimus8250
      @mattimus8250 6 месяцев назад

      @@tractorsold1 they will let anybody write electrician on the side of their truck you know. For future jobs try calling your city or town hall they sometimes have a list of reputable mechanical/ electrical contractors. Buyer Beware.

  • @johnkulpowich5260
    @johnkulpowich5260 7 месяцев назад

    When in doubt. Leave a $100 bill in the panel box. It helps

  • @rayorayado7301
    @rayorayado7301 8 месяцев назад

    That sink vent is not only useless it's not code u do not vent like that

  • @GailsonPvPwtf
    @GailsonPvPwtf 8 месяцев назад

    One thing to keep in mind, when you're bundling up the grounds in a box with different sized wires, you'll want to use the proper equipment ground size pigtail. So in that bathroom 2 gang you have the 15a lighting and that 20a receptacle circuit you'll use 12 awg pigtail and for the light right next to it you'll need 14 or bigger.

  • @dthorsvi
    @dthorsvi 10 месяцев назад

    Lots of great and useful information! Right on too!

  • @bmcd4448
    @bmcd4448 10 месяцев назад

    awesome!!

  • @mikezimmerman2786
    @mikezimmerman2786 Год назад

    Doing my new house , got a few good tips , been wiring over 50 yrs DIYER never did a whole house before. Good Video!

  • @dreamergth
    @dreamergth Год назад

    So to connect ground wires together, can i use regular wire nuts instead of using sleeves or green wire nuts?

    • @TeresaRieke
      @TeresaRieke Год назад

      Sure. Whatever you prefer. Sorry it too me so long to respond.

    • @dreamergth
      @dreamergth Год назад

      @@TeresaRieke thanks for your help brother.

  • @MrGaborseres
    @MrGaborseres Год назад

    👍

  • @hammyhan6454
    @hammyhan6454 Год назад

    thank you so much

  • @garbo8962
    @garbo8962 Год назад

    Article 90 or 100 in NEC says work to be preformed in a workman like matter. Lot of valve was sparkies guess never read that. If you install a pipe or a nipple from outside enclosure to indoor enclosure the NEC requires that you seal the wires to prevent condensation. Sloppy not taping the bare grounded conductor with white tape from the service cable.

  • @garbo8962
    @garbo8962 Год назад

    Nerds will want to use POE ( power over Ethernet ) that uses low voltage DC over Cat 5 or Cat 6 cable to power up all of their LED'S.

  • @garbo8962
    @garbo8962 Год назад

    Tips from a retired sparky with 50 years in the trade. I believe that a homeowner must never attempt to wire there entire house due to not knowing 99% of the halve million words in the NEC or the 1,000 to 1,100 code changes every new code book, local codes, energy codes , etc. While I had my electrical license I was required to attend at least 8 hours of confirmed education classes but always done 16 hours and had to pass an OSHA 10 class. I have been reading Mike Holts code question of the day and his daily code graphic and Charlie Treats code question of the day for last 20 years and still learning. Several times a home owner called me out after they failed usually easy ruff in inspections several times. Due to possible liability issues always turned them down. Never heard of needing a receptacle required on both sides of a sliding doors. In my area you must have 1 outdoor receptacle in front & rear oh homes. A receptacle must be installed within 25' of outdoor condensing ( AC ) units.White conductors not up to code. Now you must twist them with the black wire or label them so they will be able to easily locate them. 2020 code now requires that ALL residential have can outdoor service disconnect. Do now cost hundreds of $ more. Then first panel in the house and all others then considered double held requiring you to install a ground bar and using a 4 conductor SER cable from meter/ service disconnect box to indoor panel.

  • @chrismarlowe9970
    @chrismarlowe9970 Год назад

    And you can share kitchen and dining room

  • @chrismarlowe9970
    @chrismarlowe9970 Год назад

    Outlets are to be every 12ft around the perimeter of the room and 6ft off the door and every wall 24 in and greater

  • @garyfoster2665
    @garyfoster2665 Год назад

    Wow great explanation! I’m just finishing my first rough in and this is the best explanation!

  • @bobbelman4097
    @bobbelman4097 Год назад

    Dave thank you very much it was very very helpful

    • @TeresaRieke
      @TeresaRieke Год назад

      Great! So glad it was helpful!

  • @DavidGonzalez-md9je
    @DavidGonzalez-md9je Год назад

    Why is there a separate vent for the sink when the sink drain ties in the the 3" main vent?

    • @ghislainehiers5359
      @ghislainehiers5359 Год назад

      Yea I saw that and had a little chuckle 😃

    • @anthonyl5505
      @anthonyl5505 8 месяцев назад

      Because he used a combi instead of a Santee so he needed a vent before that fitting

    • @rayorayado7301
      @rayorayado7301 8 месяцев назад

      😂

  • @jbtyler523
    @jbtyler523 11 лет назад

    just so amazing that you can stay focused on God and sing this song. Amazing amazing amazing!

  • @jbtyler523
    @jbtyler523 11 лет назад

    Amazing

  • @TeresaRieke
    @TeresaRieke 12 лет назад