- Видео 218
- Просмотров 326 004
electricaltechnical@881
Индия
Добавлен 24 мар 2020
Subscribe the channel If you have sucess in the field of Electrical Engineering and practically improve your skill
this channel will explain all electrical control circuit and power circuit of Motor control circuit logic control Rlc control practically demonstration on energy meter, relay,ACB, Vcb breaker , Current transformer testing,
Pt testing , E2P. Controller, load cells, Actuators, control circuit valves,contactor, limit switch, overload relay, temperature controller, timers, wiring connection of single phase and three phase and control circuit wiring connection of all electrical and electronics based projects
this channel will explain all electrical control circuit and power circuit of Motor control circuit logic control Rlc control practically demonstration on energy meter, relay,ACB, Vcb breaker , Current transformer testing,
Pt testing , E2P. Controller, load cells, Actuators, control circuit valves,contactor, limit switch, overload relay, temperature controller, timers, wiring connection of single phase and three phase and control circuit wiring connection of all electrical and electronics based projects
gic micon 225 timer time setting how to set ontime and offtime setting
In this video time setting and control circuit wiring connection of gic micon 225 timer how to set on time setting and off time setting in gic micon 225 timer
Set time range 100msec - 10 hour any time set
Set time range 100msec - 10 hour any time set
Просмотров: 35
Видео
direct online starter control wiring connection with on off and trip indication
Просмотров 537 часов назад
In this video control circuit wiring connection of direct online starter how to connect on off and trip indication with starter Control circuit between single phase
Motor control from two locations/places control circuit wiring connection
Просмотров 359 часов назад
In this video control circuit wiring connection of one motor control from two locations/Places
Level sensor working how to control a contactor with level sensor
Просмотров 439 часов назад
In this video practically working of level sensor Use three wire sensor in which red wire is common and green wire is N.O contact with common and black wire is NC contact with common, for low level use NO contact for control the contactor and low level feedback from Nc contact of level sensor Control circuit between phase and neutral
testing of current transformer how to test ct
Просмотров 34428 дней назад
In this video how to test current transformer Practically testing of current transformer ratio
Schneider Conzerv EM6400NG Setting
Просмотров 59Месяц назад
In this video how to set CT and pt ratio in em6400ng 3 phase energy meter and basic set up
Schneider Conzerv EM6400NG energy meter reset setting , how to reset kwh reading in em6400ng
Просмотров 60Месяц назад
In this video how to reset Schneider electric Conzerv EM6400NG 3 Phase Energy Meter
Selec EM306 energy meter how to set CT ratio in em306
Просмотров 51Месяц назад
In this video how to set CT ratio in selec EM306 3 Phase energy meter and parameters set up
energy meter connection with current transformer and basic setting
Просмотров 99Месяц назад
energy meter connection with current transformer and basic setting
MC 2538 MAXTHERMO TEMPERATURE CONTROLLER SETTING
Просмотров 117Месяц назад
MC 2538 MAXTHERMO TEMPERATURE CONTROLLER SETTING
Selec tc 513 temperature controller setting
Просмотров 252Месяц назад
Selec tc 513 temperature controller setting
Automatic star delta starter wiring connection with motor
Просмотров 1,1 тыс.Месяц назад
Automatic star delta starter wiring connection with motor
Schneider Conzerv EM1000 energy meter Parameter/programming setting
Просмотров 2,1 тыс.Год назад
Schneider Conzerv EM1000 energy meter Parameter/programming setting
how to connect motor star and delta connection with dol starter
Просмотров 242Год назад
how to connect motor star and delta connection with dol starter
Automatic star delta starter wiring connection with motor
Просмотров 315Год назад
Automatic star delta starter wiring connection with motor
Contactor and Relay holding circuit, how to hold relay and contactor
Просмотров 418Год назад
Contactor and Relay holding circuit, how to hold relay and contactor
float switch wiring connection how a contactor control by float switch
Просмотров 136Год назад
float switch wiring connection how a contactor control by float switch
single phase preventer wiring connection with direct online starter
Просмотров 113Год назад
single phase preventer wiring connection with direct online starter
star delta timer gic control connection with star and delta contactor
Просмотров 302Год назад
star delta timer gic control connection with star and delta contactor
SELEC 800SD ON DELAY TIMER WORKING, TESTING TIME SETTING STAR DELTA TIMER WORKING
Просмотров 1,8 тыс.Год назад
SELEC 800SD ON DELAY TIMER WORKING, TESTING TIME SETTING STAR DELTA TIMER WORKING
Selec 800Sd Ondelay timer working connection and time setting
Просмотров 1,6 тыс.Год назад
Selec 800Sd Ondelay timer working connection and time setting
3 PHASE MOTOR RELATION IN SLIP, POLE, FREQUENCY, ROTOR SPEED & SYNCHRONOUS SPEED , NS,NR,SLIP,POLE
Просмотров 155Год назад
3 PHASE MOTOR RELATION IN SLIP, POLE, FREQUENCY, ROTOR SPEED & SYNCHRONOUS SPEED , NS,NR,SLIP,POLE
Reverse forward starter control and power circuit wiring with three phase motor
Просмотров 319Год назад
Reverse forward starter control and power circuit wiring with three phase motor
sequence starting of two motors manually
Просмотров 164Год назад
sequence starting of two motors manually
Automatic sequence starting of two motors with on delay timer
Просмотров 251Год назад
Automatic sequence starting of two motors with on delay timer
EOT crane /hoist control circuit wiring control wiring of eot crane explained in hindi
Просмотров 8 тыс.Год назад
EOT crane /hoist control circuit wiring control wiring of eot crane explained in hindi
colour code of carbon composition resistance
Просмотров 83Год назад
colour code of carbon composition resistance
खूप छान माहिती भेटली धन्यवाद
Full video banaiye sir
Full video app channel par dekh lo
ruclips.net/video/OoqrMwVIjj4/видео.html
Thank you sir
Ok
Kese set kre
Sir channel PE aap video dekh lo
Connection btao Bhai
ruclips.net/video/L_S_BlX8zjU/видео.html
Nice video ❤
In this relay to Contact One NC & NO. Which Contact is used for tripping? I have a C&S Electric LR1-D09314 relay. I am testing this process but NO contact will not make NC. I give 2x current settings 14 A but not operated.
Control is through nc contact suppose a relay whose current seeting between 1-5 amp. and current seeting is set at 3 amp. If the current value is equal or greater than 3 amp. and continuous increase than after some delay overload relay trip action occur It's NC contact become this time N.O and N.O become N.C if you want trip feedback use N.O contact than after reset again Nc become NC and NO become NO
NC contact is used for tripping
@@electricaltechnical881 NO contact which purpose is used
for tripping feedback
Nice
Thanks ❤❤❤❤
Bhai isi m auto / manual aur spp k sth lga k bnana video
Ok
V good bhai sari confusion dur ho gyi love lots
Best video of EOT crane with full explanation with practical thanks sir ji
Thanks sir
Please send your email address for contact
Half hour on or half hour off kaiese set kare
If you set the time 30 min on /30 min. off 1 - change the dip switch settings for off time 1,2 dip switch for on time 6,7 dip switch for time setting in hour 1 dip switch is off and 2 dip switch is on (off time) 6 dip switch is off and 7 dip switch is on (on time) after that select multiplier If you choose multiplier is 1 3 and 8 dip switch both on Total time adjustments is done by potentiometer knob up for off time and down for on time setting total 10 div. time setting in hour 1div. =0.1 hour 10 div.=1 hour For half hour on and off both the potentiometer knob is set on 5 div. 5×0.1=0.5 hour ,1hour =60. min. 0.5 ×60= 30min that's all
Very good sir...
Common pe pahse kais hoga ji?
Sir if phase wire is connected to common and neutral wire is connected to running winding with capacitor 2. If neutral wire is connected to common and phase wire is connected to running winding with capacitor
Bhai muzhe bhi sikhana hai contact number dedo
Bhai g bilkul channel Pe app video dekh lo
Best sir
Mera question 1) case 2 jab power DG pe shift ho rahi hai tab relay ki COMMON or NC use kar rahe hai ham to common ke supply kaha se aarhi hai ? 2) KYA HAME DG ON CONDITION ME RAKH NA PEDEGA ?
Dg contactor is hold only when relay is off state control phase of dg is connected to relay common point and is out through nc contact of relay is in series with nc contact of grid contactor and contactor dg is on
2 , No dg is not in on condition dg run in auto when power failure
sir, we can't the schematic diagram
Ok dr
Very informative video bhau
this is pro edition. till next time-;)