DCM BioServices
DCM BioServices
  • Видео 29
  • Просмотров 41 636
Thermo Fisher Scientific KingFisher Flex - How to replace the heat block and magnetic head
In this tutorial we will show you how to safely replace the magnetic head or the heat block on your Thermo Scientific KingFisher Flex.
If you don't feel comfortable performing these steps on your own instruments or you need more information about service and repair reach out to us today! dcmbioservices.com/schedule-service
Find more tutorials here: www.dcmbio.com/tutorials
Follow us on LinkedIn: www.linkedin.com/company/dcmbio/
At DCM BioServices our sole focus is to make sure you experience as little downtime in your lab as possible and that your equipment is operating at peak efficiency. Our awesome Field Service Engineers and office staff are eager to assist you.
Просмотров: 85

Видео

Thermo Fisher Scientific KingFisher Flex - How to Power On
Просмотров 542 месяца назад
In this tutorial we'll show you the correct steps to power on your Thermo Fisher Scientific KingFisher Flex System. If you don't feel comfortable performing these steps on your own instruments or you need more information about service and repair reach out to us today! dcmbioservices.com/schedule-service Find more tutorials here: www.dcmbio.com/tutorials Follow us on LinkedIn: www.linkedin.com/...
Hamilton MicroLab STAR - How To Create A Simple Transfer Method
Просмотров 1 тыс.9 месяцев назад
In this video we show you, step-by-step, how to create a simple transfer method for your Hamilton MicroLab STAR series liquid handler. Website: dcmbio.com Connect with us on LinkedIn: www.linkedin.com/company/dcmbio/ At DCM BioServices our sole focus is to make sure you experience as little downtime in your lab as possible and that your equipment is operating at peak efficiency. Our awesome Fie...
BioMek iSeries - Teaching The Deck
Просмотров 19410 месяцев назад
Learn how to teach the deck on your Beckman Coulter BioMek iSeries liquid handler. Find more tutorials here: www.dcmbio.com/tutorials Follow us on LinkedIn: www.linkedin.com/company/dcmbio/ At DCM BioServices our sole focus is to make sure you experience as little downtime in your lab as possible and that your equipment is operating at peak efficiency. Our awesome Field Service Engineers and of...
BioMek iSeries - Simple Transfer Method
Просмотров 23011 месяцев назад
Learn how to create a simple transfer method on your Beckman Coulter BioMek iSeries liquid handler. Find more tutorials here: www.dcmbio.com/tutorials Follow us on LinkedIn: www.linkedin.com/company/dcmbio/ At DCM BioServices our sole focus is to make sure you experience as little downtime in your lab as possible and that your equipment is operating at peak efficiency. Our awesome Field Service...
Tecan Evo Series: How to create a simple transfer method (96 channel head)
Просмотров 264Год назад
Learn how to create a simple transfer method for the 96 channel head on your Tecan Evo series liquid handler. Website: dcmbio.com Connect with us on LinkedIn: www.linkedin.com/company/dcmbio/ At DCM BioServices our sole focus is to make sure you experience as little downtime in your lab as possible and that your equipment is operating at peak efficiency. Our awesome Field Service Engineers and ...
Tecan Evo Series: Simple Transfer Method (8 Channel Head)
Просмотров 307Год назад
Learn how to set up a simple transfer method on your Tecan Evo Series liquid handler using the 8 channel head. Website: dcmobio.com Connect with us on LinkedIn: www.linkedin.com/company/dcmbio/ At DCM BioServices our sole focus is to make sure you experience as little downtime in your lab as possible and that your equipment is operating at peak efficiency. Our awesome Field Service Engineers an...
Laboratory Automation Integrations
Просмотров 338Год назад
Without automation your laboratory spends more time and money on simple tasks with a higher margin for error. At DCM BioServices we can help you integrate multiple automation instruments to work together to achieve complex tasks. With custom integrations you can often achieve this level of automation using instruments you already own. Schedule a consultation today to find out how you can elimin...
BioTek ELx405 - Troubleshooting a 1400 Vacuum Error Code
Просмотров 2,4 тыс.2 года назад
In this tutorial we will show you how to troubleshoot the infamous 1400 Vacuum Error Code on the BioTek ELx405 Microplate Washer. There are several different issues that can cause this issue and we'll cover most of them here. As always, if you have any questions or don't feel comfortable performing these steps on your own, please reach out to us at service@dcmbio.com and we'll be happy to help!...
Biomek FXp and NXp - Teaching The Deck on Software Version 4.2 or higher.
Просмотров 4432 года назад
In this tutorial we will show you how to teach the deck on a Beckman Coulter Biomek FX or NX platform using the Biomek 4.2 software. In earlier versions you needed to replace one of the Span8 pod mandrils with a teaching tool. This is no longer required. As always, if you have any questions or don't feel comfortable performing these steps on your own, please reach out to us at service@dcmbio.co...
Biomek FX/NX - How to re-use liquid handler pipette tips
Просмотров 1,6 тыс.3 года назад
Across the world there is a shortage of automated liquid handler pipette tips. If you are using a Biomek, this solution will allow you to recover, wash, and re-use the tips you already have using a tip shuck to tip box. Reach out to us at service@dcmbio.com for more information. The solution in this video will work on Biomek FX/NX, FXp/NXp instruments. As always, if you have any questions or do...
BioTek ELx405: Prepping for a move, shipping, and long shutdown.
Просмотров 4024 года назад
Do you need to move or ship your BioTek plate washer? It's best to perform this long shutdown procedure before you do to protect the more sensitive components of your instruments. Parts Available: Biotek Manifold channel-end seals, Pack of 12: a.co/d/2coOCx9 Biotek Washer Manifold O-Ring: a.co/d/am04wP4 Biotek Washer Waste Tubing Set: a.co/d/erXOJ2k Biotek 4L dispense bottle with filter: a.co/d...
BioTek Plate Washer and BioStack Alignment Tutorial
Просмотров 1,7 тыс.4 года назад
In this video we show you how to align your BioStack to your BioTek Plate Washer. As always, if you have any questions or don't feel comfortable performing these steps on your own, please reach out to us at service@dcmbio.com and we'll be happy to help! You can find more awesome tutorials at dcmbioservices.com/tutorials! Parts Available: Biotek Manifold channel-end seals, Pack of 12: a.co/d/2co...
Agilent VSpin Centrifuge: Teaching Bucket Positions
Просмотров 4995 лет назад
There are lots of ways that the buckets on your VSpin centrifuge can become out of alignment. Fortunately, its pretty easy to re-teach the positions and get back up and running. As always, if you have any questions or don't feel comfortable performing these steps on your own, please reach out to us at service@dcmbio.com and we'll be happy to help! You can find more awesome tutorials at dcmbiose...
BioTek ELx405: Building A Wash Protocol
Просмотров 2,9 тыс.5 лет назад
In this tutorial we'll walk you through building a wash protocol on your BioTek Plate Washer. As always, if you have any questions or don't feel comfortable performing these steps on your own, please reach out to us at service@dcmbio.com and we'll be happy to help! You can find more awesome tutorials at dcmbioservices.com/tutorials! Parts Available: Biotek Manifold channel-end seals, Pack of 12...
BioTek ELx405/406: Using the Adjust Utility
Просмотров 1,3 тыс.5 лет назад
BioTek ELx405/406: Using the Adjust Utility
Tutorial: Changing the Barrels on an Agilent / Velocity 11 Multi-Channel Head
Просмотров 1,9 тыс.5 лет назад
Tutorial: Changing the Barrels on an Agilent / Velocity 11 Multi-Channel Head
Loading the Seal in an Agilent PlateLoc
Просмотров 1,5 тыс.5 лет назад
Loading the Seal in an Agilent PlateLoc
BioMek FX/NX: Teaching the Deck with a Span8 Pod
Просмотров 1,3 тыс.5 лет назад
BioMek FX/NX: Teaching the Deck with a Span8 Pod
BioMek FX/NX - Multi-Channel Pod: Teaching The Deck
Просмотров 1,2 тыс.5 лет назад
BioMek FX/NX - Multi-Channel Pod: Teaching The Deck
Basic Troubleshooting For Your Terumo SCD BII Tube Welder
Просмотров 6 тыс.5 лет назад
Basic Troubleshooting For Your Terumo SCD BII Tube Welder
BioMek Fx/NX: How to frame the grippers on the multi-channel pod
Просмотров 1,2 тыс.5 лет назад
BioMek Fx/NX: How to frame the grippers on the multi-channel pod
How to purge air from a BioMek FX/NX Span8 Pod
Просмотров 1,1 тыс.5 лет назад
How to purge air from a BioMek FX/NX Span8 Pod
BioTek ELx405: Waste Line Maintenance
Просмотров 1,2 тыс.5 лет назад
BioTek ELx405: Waste Line Maintenance
BioTek ELx405: Basic Manifold Maintenance
Просмотров 6 тыс.6 лет назад
BioTek ELx405: Basic Manifold Maintenance
How to change the grippers on a BioMek FX/NX Multi-Channel Pod
Просмотров 5626 лет назад
How to change the grippers on a BioMek FX/NX Multi-Channel Pod
How to create a simple transfer method on a BioMek FX or NX
Просмотров 3,5 тыс.6 лет назад
How to create a simple transfer method on a BioMek FX or NX
How to change the head on a BioMek FX/NX multi-channel pod
Просмотров 9006 лет назад
How to change the head on a BioMek FX/NX multi-channel pod
Biomek FX/NX - How To Eject Tips
Просмотров 1,7 тыс.10 лет назад
Biomek FX/NX - How To Eject Tips

Комментарии

  • @someguytu
    @someguytu 28 дней назад

    is there a way for the user to align these two once installed?

  • @dianag8470
    @dianag8470 3 месяца назад

    When I click on C-POS, I get an error message 8306 (serial communication timed out). I tried reconnecting the cable and turning it off but it doesn’t work

    • @dcmbioservices
      @dcmbioservices 3 месяца назад

      Is your Biostack connected to an ELx405 or EL406? If so, you'll need to first enable Biostack Mode. This is done by navigating to SETUP -> BIOSTACK -> BIOSTACK UTILITIES -> CONF and changing from Manual Mode to Biostack Mode.

  • @LangstonGash-fo3ml
    @LangstonGash-fo3ml 6 месяцев назад

    How would one go about doing a full plate transfer? For example, if I had a 96-well plate and wanted to fill each individual well, how would I do that?

    • @dcmbioservices
      @dcmbioservices 6 месяцев назад

      Are you trying to fill each well with a different liquid? Feel free to reach out to service@dcmbio.com and we'd be happy to help you out. We'll make a video for it too!

    • @jonasfyrestam9877
      @jonasfyrestam9877 6 месяцев назад

      If your dispense sequence covers the whole target plate it will fill each well with liquid. If you want to adjust the number of wells each time you run your method it becomes a little bit more complicated.

    • @LangstonGash-fo3ml
      @LangstonGash-fo3ml 6 месяцев назад

      @@jonasfyrestam9877 tried doing that before and it didn't work

  • @SherylSanchez-sj2vy
    @SherylSanchez-sj2vy 6 месяцев назад

    What if there is no initialize step in the method editor?

    • @dcmbioservices
      @dcmbioservices 6 месяцев назад

      There is a setting that needs to be enabled in the software in order for that step to be available. Email us at service@dcmbio.com and we can send you the procedure.

  • @-qi3wk9ik1m
    @-qi3wk9ik1m 11 месяцев назад

    resech fromRehmat Kreem LHE pakistan

  • @johannaleinmueller7525
    @johannaleinmueller7525 Год назад

    Great tutorial! Thanks!

  • @R33F3RMONSTER
    @R33F3RMONSTER Год назад

    Very helpful!

  • @andrewauerbach3441
    @andrewauerbach3441 2 года назад

    Is there a video or step-by-step for how to create a washing step for a 384-well plate, where the head stamp is still a 96-head?

    • @dcmay1234
      @dcmay1234 2 года назад

      We do not have a video outlining 384 wash step generation, but the procedure is very similar to the 96 wash step. Only ELx405 Select, Select CW, and HT units are capable of washing 384 well plates with the 96 format manifolds, so please be sure to check your washer model. When creating the wash protocol, simply specify the plate type as 384. You will need to specify the wash format after selecting number of wash cycles, with options for Plate Format (each cycle is performed on the entire plate before proceeding) or Sector Format (each cycle is completed in a quadrant before moving on to the next quadrant). We recommend double-checking the dispense and aspirate alignments using the adjust utility to confirm the pin positions. Most 384 well plates will run with the default 0,0 positions for X and Y, but non-standard plates will require an offset. The adjust utility will only need to be used for the first quadrant wells, as the washer will calculate the other quadrant locations automatically.

  • @clinicallyinane8098
    @clinicallyinane8098 2 года назад

    Very nice tutorial! It was easy to understand and follow along with, and it helped me out a ton.

  • @stephanieloehr8564
    @stephanieloehr8564 2 года назад

    How many times can the tips be reused?

    • @dcmbioservices
      @dcmbioservices 2 года назад

      Good, high quality tips should be able to handle 5-10 uses before they should be discarded.

  • @carolinamisawa9752
    @carolinamisawa9752 3 года назад

    I have a problem with my machine. Every time I put her to run she accuses that the door is open. for it to work normally, I have to turn it all off, close the program and then call to go home all. would there be a way to turn off this sensor of hers for it to run normally?

    • @dcmbioservices
      @dcmbioservices 2 года назад

      Send us a message at service@dcmbio.com with this problem description so we can help you get back up and running!

  • @farhadtorkaman6282
    @farhadtorkaman6282 3 года назад

    Hi , Thank you for your perfect explain , please help me about ( 0200 ) Error in ELX405 🌲⚘

    • @dcmbioservices
      @dcmbioservices 2 года назад

      Reach out to us at service@dcmbio.com for specific service questions. We would love to help you.

    • @farhadtorkaman6282
      @farhadtorkaman6282 2 года назад

      This error was about step motor , thank you 🖐🌷

  • @pkaur6136
    @pkaur6136 3 года назад

    thank you

  • @zrssrot
    @zrssrot 3 года назад

    Dear sir my Elx405Ls washer prime key not working.. Without prime Im unable to run the wash, if I run it giving me error 1500 plz advice me to solve the problem

    • @dcmbioservices
      @dcmbioservices 2 года назад

      Reach out to us at service@dcmbio.com for specific service requests. We would love to get you back up and running.

  • @yulizatafoyaalvarado121
    @yulizatafoyaalvarado121 4 года назад

    Thanks, very useful!