Vacuum Circuit Breaker (Areva Make)
Просмотров 1,2 тыс.2 года назад
Vacuum Circuit Breaker (Areva Make)
Medium Voltage Bush short circuit with Body (Earth Fault) RM6 schneider.
Просмотров 2,2 тыс.2 года назад
medium voltage RMU bush Short circuit with body RM6 schneider RMU.
Replacing Silica Gel In 1000KVA Transformer
Просмотров 8472 года назад
Transformer#Silica gel#
Relay Testing (secondary Injection test) Using FREJA 306 Test kit.
Просмотров 17 тыс.2 года назад
Relay testing #FREJA 306#Procedure#
ATS Controller Manufacturer By DAIF.
Просмотров 2342 года назад
DAIF controller #ATS#500kw genset.
Grounding Test (Earth Testing)
Просмотров 2262 года назад
Earth value #PI- Pit value #below 5 ohm#GI- Gret value- below 1ohm.
Configuration of power quality meter GE PQM II.
Просмотров 2,7 тыс.3 года назад
configuration of PQM settings of CT,PT conntion and it's ratio all required monitoring parameters of GE PQM meter.
How To Read The Power Quality Meter GE
Просмотров 7703 года назад
How To Read The Power Quality Meter GE
Circuit Breaker ABB VD4
Просмотров 2,6 тыс.3 года назад
Circuit Breaker ABB VD4
ACB Breaker Parts and its functions
Просмотров 5854 года назад
ACB Breaker Parts and its functions
Schnider Air circuit breaker Maintenance
Просмотров 6674 года назад
Schnider Air circuit breaker Maintenance
500A MCCB Primary injection test on field...
Просмотров 6644 года назад
500A MCCB Primary injection test on field...
Primary injection test for circuit breaker
Просмотров 25 тыс.4 года назад
Primary injection test for circuit breaker
Vacuum Circuit breaker service
Просмотров 1584 года назад
Vacuum Circuit breaker service
MCCB Motorized Operations and wiring
Просмотров 55 тыс.4 года назад
MCCB Motorized Operations and wiring
Automatic Transfer Switch (ATS) Test Run
Просмотров 1934 года назад
Automatic Transfer Switch (ATS) Test Run
How to perfrom transformer truns ratio test.
Просмотров 1,6 тыс.5 лет назад
How to perfrom transformer truns ratio test.
How to perform magnetic current test in transformer.
Просмотров 9 тыс.5 лет назад
How to perform magnetic current test in transformer.
Cable locator radiodetection
Просмотров 3,1 тыс.5 лет назад
Cable locator radiodetection
How to find the cable fault location
Просмотров 1,9 тыс.5 лет назад
How to find the cable fault location
Current transformer testing
Просмотров 7 тыс.5 лет назад
Current transformer testing
Potential transformer 13.8kv
Просмотров 2265 лет назад
Potential transformer 13.8kv
How to test the Current transformer
Просмотров 1,6 тыс.5 лет назад
How to test the Current transformer
How to do ACB trip setting in different protection
Просмотров 5845 лет назад
How to do ACB trip setting in different protection
How to IR test in circuit breaker
Просмотров 4,2 тыс.6 лет назад
How to IR test in circuit breaker
How to find out cable size
Просмотров 1716 лет назад
How to find out cable size
Ups systems
Просмотров 746 лет назад
Ups systems
How to perform magnetic balance test in transformer
Просмотров 6 тыс.6 лет назад
How to perform magnetic balance test in transformer
How to measure insulation resistance in cable
Просмотров 5176 лет назад
How to measure insulation resistance in cable

Комментарии

  • @code.cracking
    @code.cracking День назад

    Hi Mani, I need your help with a similar meter, how can I reach you?!

  • @code.cracking
    @code.cracking День назад

    Hi Mani, I need your help with a similar meter, how can I contact you please 🙏

  • @gajananraipure9242
    @gajananraipure9242 12 дней назад

    Thank you such best video

  • @technicaldepartment2378
    @technicaldepartment2378 Месяц назад

    How to we set this on auto mode during change over

  • @deep308
    @deep308 2 месяца назад

    Sir DG auto turns on but changeover mccb is not on in auto mode .manual must be done. What could be the problem.

  • @SergioCElias
    @SergioCElias 2 месяца назад

    Parabens!

  • @twinklebly7453
    @twinklebly7453 3 месяца назад

    Just got my job promoted and face this problem. Now I will use this video to solve this problem. Thanks a lot guys. Camera man is also a pro.

  • @mohanrajmohan988
    @mohanrajmohan988 3 месяца назад

    Ji, is there possible to test 2nd harmonic by this kit

  • @mayrakadian1997
    @mayrakadian1997 4 месяца назад

    I need your support

  • @hemantverma5625
    @hemantverma5625 4 месяца назад

    Toug tester ko data hold mode mai rakhate to mccb ka actual triping current ka pata chalta

  • @bhaskerrohilla8740
    @bhaskerrohilla8740 4 месяца назад

    Price of this kit

  • @Imran30197
    @Imran30197 6 месяцев назад

    Mani g what a master class video it is Hats off to you Imran from Taif

  • @michelvidallo7288
    @michelvidallo7288 6 месяцев назад

    it did not tripped in 375A it tripped more than 375A about 390A...Circuit breaker is not ok if its like that

  • @mhdbadsh6944
    @mhdbadsh6944 7 месяцев назад

    This Smart RMU made in KSA ALFANAR ELECTRIC,2015 to 2019 i was worked there, which company bro r u working

  • @MuntathirAlshidi
    @MuntathirAlshidi 8 месяцев назад

    Very nice explanation, thanks bro❤

  • @KMinformation14
    @KMinformation14 8 месяцев назад

    When you will be told later

  • @prabhjotmanro8154
    @prabhjotmanro8154 10 месяцев назад

    Power quality Meter (PSPCL) reports how to read ??

  • @SergioCElias
    @SergioCElias 10 месяцев назад

    Top 10 seu vídeo!

  • @manikandan-lx6gr
    @manikandan-lx6gr 11 месяцев назад

    Thank you ji🎉

  • @HenryKyawzin
    @HenryKyawzin 11 месяцев назад

    Whre r you testing ? in Singapore ?

  • @tapatiojesus
    @tapatiojesus Год назад

    Can you show the battery compartment to see what battery use it

  • @30mAkills
    @30mAkills Год назад

    Very rare and useful video along with safety tips. An arc welding machine of suitable amps can be converted as injecting source.

  • @HARSHTECH01
    @HARSHTECH01 Год назад

    Upload video in English language

  • @ONLLY1994
    @ONLLY1994 Год назад

    Hello!We are manufacturer of Electric protector relay test in China,hope to cooperate with your company if have a chance in future.

  • @elemohamed1977
    @elemohamed1977 Год назад

    Thank you A1=N B4= LINE TO MOTOR A4=LINE TO ORDER TO OFF A2=LINE TO ORDER TO ON

  • @zaitonyahya4768
    @zaitonyahya4768 Год назад

    Tj4092 @tj4092@135

  • @avijit06idealvlog
    @avijit06idealvlog Год назад

  • @kalifatoina3892
    @kalifatoina3892 Год назад

    Hi how are you

  • @praveenmenezes7399
    @praveenmenezes7399 Год назад

    Nice and very informative video ..thanks

  • @naushadmohammad2784
    @naushadmohammad2784 Год назад

    Breaker apm rating of this motor

  • @raedsaqallah5049
    @raedsaqallah5049 Год назад

    Nice explanation thank you

  • @ricardojosequinterofragozo7468

    Como cambiar DISPLEY

  • @AbdulAzeez-im1sb
    @AbdulAzeez-im1sb Год назад

    Informative video . Please make a video on CPC100, SVERKER and CB Analyzer kits also. Thanks

  • @Diegoramos10
    @Diegoramos10 Год назад

    Hello. I have a Freja 300 and we need the FrejaWin 2.0 software as the selection knob is damaged. Could you send a download link? Thanks.

    • @manibalan7524
      @manibalan7524 Год назад

      Hii , I am sorry now I am not using that, let me check.

    • @Diegoramos10
      @Diegoramos10 Год назад

      @@manibalan7524 Ok! Thanks!

    • @manibalan7524
      @manibalan7524 Год назад

      Protection Guide. Please download your requuire software .

    • @SergioCElias
      @SergioCElias 10 месяцев назад

      Vídeo muito bom. Parabéns!

    • @SergioCElias
      @SergioCElias 10 месяцев назад

      Faça mais videos sobre a Freja 300?

  • @user-hu4if6xw8p
    @user-hu4if6xw8p Год назад

    Pahele english sikhalo. Fir decide karalo ki 1 ma, 10 ma or 100ma ok?

  • @prabuvanniyappan7966
    @prabuvanniyappan7966 Год назад

    நன்றி

  • @shashankthakur1105
    @shashankthakur1105 Год назад

    Voltech engineers?

  • @amitpagare5946
    @amitpagare5946 2 года назад

    Please make video on ICOG panel maintenance 🙏🙏🙏🙏

  • @amitpagare5946
    @amitpagare5946 2 года назад

    Never delete this video. 🙏🙏🙏🙏

  • @amitpagare5946
    @amitpagare5946 2 года назад

    🙏🙏🙏 make video on ICOG panel maintenance 🙏🙏🙏

  • @agusreva8537
    @agusreva8537 2 года назад

    Bahsa indonesia

  • @nagarajvijayarangan2679
    @nagarajvijayarangan2679 2 года назад

    Tamil speak and 2moterized interlock bro...

  • @carrierelcetrical6907
    @carrierelcetrical6907 2 года назад

    Full video in work

  • @amarjeetsingla5026
    @amarjeetsingla5026 2 года назад

    Manual charge करते करते स्पिंग एक जगह अटक गया और vcb चार्ज नहीं हुई क्या जाये बताना सर् plz

  • @eng.mzaalalmodaberiy3882
    @eng.mzaalalmodaberiy3882 2 года назад

    Hi, bro can you sharing your number to me ?

  • @maniyarasanrenganathan7313
    @maniyarasanrenganathan7313 2 года назад

    Thank you brother

  • @amitpagare5946
    @amitpagare5946 2 года назад

    Very informative video 🙏🙏🙏

  • @samirchakib7354
    @samirchakib7354 2 года назад

    Détecter les câbles sans électricité ??

  • @samirchakib7354
    @samirchakib7354 2 года назад

    How deepth

  • @priyarani1900
    @priyarani1900 2 года назад

    Sir Can you please tell, why you put 250% of the rated current of CB on single pole ? Please explain sir

    • @integraxnine745
      @integraxnine745 6 месяцев назад

      It's because the more the current is above rated value, the quicker the breaker trips. Let's say he set it at 110% then it would take something like 30 minutes to trip which would make the video longer.