InterDam B.V.
InterDam B.V.
  • Видео 54
  • Просмотров 27 557

Видео

InterDam, Sustainability through refurbishment
Просмотров 186Год назад
InterDam fire- and blast resistant doors are built to last for decades, if properly maintained. Recently InterDam was approached by one of our customers with the question if doors manufactured and installed in 1998 could be refurbished to last for another 20 years. The doors had been working to satisfaction for the past 25 years and by extending their life the customer could reduce costs, waste...
Hollandse Kust Noord Offshore Wind Substation
Просмотров 329Год назад
Last week our CEO Fraser Weir had the privilege of being invited by Tennet to visit the Hollandse Kust Noord offshore wind substation as part of Tennet’s Contractor Day. InterDam is proud to have supplied the architectural scope for this project, in collaboration with our valued customers Smulders and Equans. Many thanks to Tennet and Crosswind for organising an informative (and sunny) day! int...
InterDam reduces carbon footprint.
Просмотров 2582 года назад
With the recent installation and commissioning of roughly 1500 pieces of solar panels, InterDam reduces its carbon footprint and contributes to the worldwide quest for a greener energy supply. For more than a decade InterDam produces and supplies blast- and fire-resisting doors, walls, and windows to the global offshore wind industry and is therefore already very committed to the ‘green’ energy...
InterDam demonstrates the feasibility of mounting 14 meter (46ft) long G21 Fire Panels.
Просмотров 2242 года назад
InterDam demonstrates the feasibility of mounting 14 meter (46ft) long G21 Fire Panels.
IDM Fire escape doors for tunnels, tested and approved
Просмотров 2162 года назад
Specially tested and certified fire resistant doors provide escape routes in tunnels in the event of an accident. The enclosed space and passing traffic of a tunnel present unique challenges for a door. The various tests can be seen in this video.
Gen II Fire Post Blast Test
Просмотров 1902 года назад
Blast walls and fire walls need to be able to resist fire after an explosion event as well. To confirm these capabilities, InterDam has performed a series of Fire-Post-Blast tests, in this case of a H60/H120 fire after an greather than 1.0 bar explosion. @InterDam
InterDam HHF SLS Jetfire Test
Просмотров 1022 года назад
InterDam HHF SLS Jetfire Test
The production process of G21 Fire Panels
Просмотров 2042 года назад
InterDam’s G21 Fire Panel, the sandwich panel fire wall system available in A60 to H120 fire ratings. In this short movie you can see the (automated) production process of these G21 Fire Panels! G21 Fire Panel is a lightweight, 100% tested and easy to install (1 m² per hour) wall for your project! For more information: www.interdam.com
Heavy Duty InterDam door with panic opening device
Просмотров 822 года назад
Demonstration of the Heavy Duty InterDam Door with a panic opening device. For more information: visit our website www.InterDam.com
Jet fire test IDM Propanel 120 minutes
Просмотров 1822 года назад
Jet fire test performed on a fire wall ‘IDM-ProPanel’ The IDM Propanel wall test lasted for over 2 hours and the wall succesfully passed the jet fire tested according to standard ISO 22899-1 InterDam is specialized in passive fire and blast protective solutions and has the expertise in jet fire resistant applications such as walls, doors, and windows. Visit us for more information on www.interd...
InterDam G21 Fire Panel Penetration test - A60 fire resistant
Просмотров 1422 года назад
The A60 fire rated G21 FirePanel has succesfully been fire tested with air duct penetrations. This movie shows the integrity and stability of the sandwich panel system including the penetrations in the wall. Learn more about the G21 Fire Panel on www.InterDam.com
InterDam G21 FirePanel H120 successful Fire test
Просмотров 432 года назад
InterDam succesfully tested the G21 FirePanel for H120 Fire rating. This test took place on April 28th, 2014 at the BRE test facility in Watford, UK. With the global introduction of the H-rated G21 FirePanel, InterDam offers hazardous industries the same easy-to-install, light-weight, cost-effective solution for all fire rated walls.
Air permeability test of the G21 Fire Panel by InterDam
Просмотров 832 года назад
In this video, the air permeability of a typical wall element 3.6 m wide and 3.0 m high is measured in accordance with EN 12114 "Thermal performance of buildings Air permeability of building components and building elements Laboratory test method". For this purpose six G21 Fire panels are mounted to an air tight welded steel frame. During the test procedure the total wall element is exposed to ...
Airtightness of panelfixing test of G21 fire panel (1/2)
Просмотров 212 года назад
Fixing of G21 Firepanel on 3 mm support structure with Ejot JT3 D 6H 5,5/6,3 x 147 E16. G21 fire panel: the approved A60 fire wall of the 21st century.
Airtightness of panelfixing test of G21 fire panel (2/2)
Просмотров 182 года назад
Airtightness of panelfixing test of G21 fire panel (2/2)
Succesful A60 fire test for G21 Fire panel @48 minutes (1/5)
Просмотров 592 года назад
Succesful A60 fire test for G21 Fire panel @48 minutes (1/5)
Succesful A60 fire test for G21 Fire panel @60 minutes (2/5)
Просмотров 342 года назад
Succesful A60 fire test for G21 Fire panel @60 minutes (2/5)
Succesful A60 fire test for G21 Fire panel @68 minutes (3/5)
Просмотров 192 года назад
Succesful A60 fire test for G21 Fire panel @68 minutes (3/5)
Succesful A60 fire test for G21 Fire panel @86minutes (4/5)
Просмотров 322 года назад
Succesful A60 fire test for G21 Fire panel @86minutes (4/5)
Succesful A60 fire test for G21 Fire panel @90 minutes (5/5)
Просмотров 352 года назад
Succesful A60 fire test for G21 Fire panel @90 minutes (5/5)
Fire Post Blast test sandwich panels
Просмотров 1892 года назад
Fire Post Blast test sandwich panels
Free span categories of G21 Blast Sandwich Panels
Просмотров 3872 года назад
Free span categories of G21 Blast Sandwich Panels
G21 Fire Window A60 fire test
Просмотров 3193 года назад
G21 Fire Window A60 fire test
Fire Post Blast test heavy duty doors
Просмотров 1243 года назад
Fire Post Blast test heavy duty doors
Fire test XL door InterDam
Просмотров 1843 года назад
Fire test XL door InterDam
InterDam Generation IV G21 Fire Panel & Blast Panel Tests
Просмотров 1893 года назад
InterDam Generation IV G21 Fire Panel & Blast Panel Tests
Helwin Bèta wind project by InterDam
Просмотров 3763 года назад
Helwin Bèta wind project by InterDam
Maintenance & repair spare parts in stock
Просмотров 1233 года назад
Maintenance & repair spare parts in stock
Fire Post Blast tested and certified walls, doors & windows
Просмотров 7793 года назад
Fire Post Blast tested and certified walls, doors & windows

Комментарии

  • @bboth4029
    @bboth4029 Год назад

    Nice video and great way to reduce carbon footprint indeed!

  • @bboth4029
    @bboth4029 2 года назад

    Nice! Good to see that InterDam tunnel doors are ticking all the right boxes👍

  • @pumco7671
    @pumco7671 3 года назад

    Hello people

  • @brockstout2194
    @brockstout2194 4 года назад

    What happens if it got hit with a second blast after the fire