- Видео 470
- Просмотров 336 388
My-Automation Sensor & Controller
Малайзия
Добавлен 28 окт 2019
Видео
Data anylysis KRN1000 setting time & print
Просмотров 14Месяц назад
Data anylysis KRN1000 setting time & print
AUTONICS KRN1000 CONNECT USING CONVERTER "SCM-US48I" RS485 TO USB ON DAQMASTER SOFTWARE
Просмотров 19Месяц назад
AUTONICS KRN1000 CONNECT USING CONVERTER "SCM-US48I" RS485 TO USB ON DAQMASTER SOFTWARE
Autonics TK4 deviation high/ low reverse alarm
Просмотров 47Месяц назад
Autonics TK4 deviation high/ low reverse alarm
Autonics CN series input 0 - 10vdc input
Просмотров 772 месяца назад
Autonics CN series input 0 - 10vdc input
AUTONICS TK4 HEATING HYSTERYSIS 100 % DIFFERENT SET VALUE 100 OUTPUT USING HEAT /ONOFF MODE
Просмотров 593 месяца назад
AUTONICS TK4 HEATING HYSTERYSIS 100 % DIFFERENT SET VALUE 100 OUTPUT USING HEAT /ONOFF MODE
Autonics TK4 14RN input 100mv. ALM Deviation low 0.1 ,Main output ,set value 2.0
Просмотров 853 месяца назад
Autonics TK4 14RN input 100mv. ALM Deviation low 0.1 ,Main output ,set value 2.0
TX4S-B4R with hysterysis may change @ set value
Просмотров 563 месяца назад
TX4S-B4R with hysterysis may change @ set value
AUTONICS TCN4S-24R Hysterysis .High limit alarm . alarm 20 minus 5 ahys.
Просмотров 523 месяца назад
AUTONICS TCN4S-24R Hysterysis .High limit alarm . alarm 20 minus 5 ahys.
AUTONICS KRN100 PRINT EVERY 1 HOUR GRAPH 20MMH
Просмотров 244 месяца назад
AUTONICS KRN100 PRINT EVERY 1 HOUR GRAPH 20MMH
Autonics TK4 pressure scalling hysterysis
Просмотров 964 месяца назад
Autonics TK4 pressure scalling hysterysis
KRN100 input 4 to 20mA setup wiring & scalling
Просмотров 144 месяца назад
KRN100 input 4 to 20mA setup wiring & scalling
TK4 input disconnected prompt alarm.Pucc high alarm set 30% = 10 mA signal.
Просмотров 824 месяца назад
TK4 input disconnected prompt alarm.Pucc high alarm set 30% = 10 mA signal.
Autonics CN-6400-V1 + Encoder E40S6-1024-3-T-24
Просмотров 644 месяца назад
Autonics CN-6400-V1 Encoder E40S6-1024-3-T-24
TK4 R4RN TRANSMISSION OUTPUT UNABLE SET 0 mA.
Просмотров 1464 месяца назад
TK4 R4RN TRANSMISSION OUTPUT UNABLE SET 0 mA.
KRN1000 present value high shown at alarm list
Просмотров 165 месяцев назад
KRN1000 present value high shown at alarm list
Autonics kn2400w compressor low alarm
Просмотров 655 месяцев назад
Autonics kn2400w compressor low alarm
AUTONICS BF5R-D1-N ( NPN output signal ) wiring with relay 24vdc
Просмотров 2355 месяцев назад
AUTONICS BF5R-D1-N ( NPN output signal ) wiring with relay 24vdc
AUTONiCS KRN100 without paper to print
Просмотров 655 месяцев назад
AUTONiCS KRN100 without paper to print
Please reset connection?
saya ada soalan 1) how to change kpa - mpa 2) how u set limits value range for indicate red colour and red colour value?
Hi There. on paramater 1 on "Unit" change to Mpa.Its had program as desire unit in the device.
2nd ) on parameter 2 on "Clor " select colour desire only show for present value.please download datasheet.
thank you so much, if its possible, can you demonstrate a video for it?
How can I connect TK4S series with mobile apk DAQMaster ? What device i need to connect both ?
HI sir ,For Mobile Daqmaster im not yet testing
I am interested 🎉
Hi ? It can measures humidity If it ,what is the right sensor for that operation
Hi adamtolon Autonics THD series. you may search in Autonics.com website for manual datasheet
Hi, could you show how to set this sensor to detect only black color like your video?
How to setting timer auto reset and always cycle with ct6s-1p
thanks for clarification
thanks for the clarification
wiringnya
Kamu download MP5 manual.dalam ada cara wiring.
Por favor el video en español Gracias
bang aku mau buat counter yang ada memori saving. jadi ketika mati listrik data barang yang sudah terhitung tidak hilang. kira kira pakai apa ya bang?
Kamu nanya autonics indonesia seller ya
What is the cable for programming?
Rs485 autonics model scm-us48i
bro...model ni output 240vac ke 24vdc? saya nak control lab incubator..heater 240vac..lagi 1, ada menu calibrate temperature sensor x?maknanya untuk set offset sensor
output 240VAC ,"out 1" pin 6 & 7 relay output guna contactor pada heater. Calibrate present value pada TCN model ada pada parameter 2 "INB" @ offser present value.Tolong download dari website autonics.com.Terima kasih
Sensor model?
PR12-4DN
Pls help. I am using sick speed sensor in place of the encoder. And using MP5Y pulse meter. I need to measure the speed of a motor of speed 495 rpm. What should be the setting in MP5Y ? Pls help
U need set npn or pnp . Use default psac & psay.
@@my-automationsensorcontrol4358 thanks
How to connect this multimeter until he can read the output of the controller?
pin terminal 3 & 4
please download from website for Tk4 series datasheet www.autonics.com
Tank boiler heater
design mcm nih utk psg dekat mana ya??
Español plis.
De que confección para pausar
😊
Bang ku mau bikin counter meter klo maju plus kalo mundur minus bisa gak?
Bole bang hanya guna parameter mode "UdC". Maksud up & down count.
Plz share the manual
Hi Sir. u may download from www.autonics.com. website
@@my-automationsensorcontrol4358 I really appreciate it Sr
nice video buddy, why don't you throw it in a dumpster
How did you do this? Help me
Hi Sir,u may get ur local autonics dealer for support.
Tegangan inputny berapa kah?
Contact input . Tuan boleh check manual LE4S
Permisi
Inputny berapa?
Set tem is 170 and actual is upto 250 c Continue power on from 4 no point for ssr . Pls suggest
TK4S continue power on ssr pls suggest
Pls send me wiring diagram for it !
Pls download Bw40 manual/ datasheet from www.autonics.com
can this timer connect to plc
Yes can.model CT4S-1P4T
Saya pakai untuk level sensor, macam mana nak set output relay untuk high dan low? Atau memang boleh set 1 level sahaja?
Boleh ,follow step ini : ruclips.net/video/6cb3w91sgY0/видео.html&ab_channel=AutonicsCorporation
is that out1 is for control output alarm?means is the value is high, then it triggered out1 right?
Greeting Sir, Yes its control output relay "On" or "Off " for this model ( main output is relay) when your set value Example: 4 mA = 0 celsius / 20 mA= 100 celsius.set value 50 celsius its cut off after 50 celsius
What if the reset button was made automatic? what tools are needed thank you
Thank you for response after lock how to unlock and we can decrease the value of sv value or not please give your response
U can unlock at same parameter 5 & set the Set value.
hi if i set the set value of temeperature is 150deg c, then some one changing the set value it does not change is there any chance to fix the permanant value.
on parameter 5 ,activate " lock" . For set value
Bisakah di setting utk pengukuran pressure?
Bisa Mas ,Contoh input 4 to 20mA bersamaan 0 bar to 10 bar
@@my-automationsensorcontrol4358 apa ada video setting tutorialnya?
kalo Al-2 dan muncul L L L L itu kenapa ya ?
kalo Al-2 muncul LLLL kenapa ya ?
Ta stand for what in manual
time setting
Thanks! That is what I needed!
me too
I tried,but cannot got result
You call autonics seller near you , for technical support.
My model tks4- r4cn can do this
Sir, i have doubt about tk4s series ,what i say means now my setting is heating L-SV 25°c and H- sv 50°c i need current output 4 to 20ma or voltage output 0 to 10 v in the range temperature 25 ° means 0 v or 4ma and 50° means 10v or 20 ma .how to do settings pls make video .my sensor rtd pt 100 . And How to temp valve transfer to BMS SYSTEM
u may copy title & refer this video "AUTONICS TK4 SERIES PV TRANSMISSION ANALOG OUTPUT SETTING( ONLY DESIGNATED MODEL )REFER ORDER INFO"
'promo sm'
If i use ct6m-10 autonics, still can sir? So how do settting the parameter sir, help me🙏
I use encoder 1024
A better description and five seconds of introduction would have made this video much clearer. Nonetheless, it solved my problem (making the Autonics counter reset automatically when it reaches the preset counter value)! Thanks!
Thank u @mpazsti
How to set parameters one by one details video update
Please show wiring diagram of this video
Emg tidak bisa bolak balik