OIL TO GAS CONVERSION INSTALLATION WITH ZONE VALVES
OIL TO GAS CONVERSION INSTALLATION WITH ZONE VALVES
Просмотров: 218

Видео

ZONED DAMPER SYSTEM INSTALLATION
Просмотров 53 месяца назад
ZONED DAMPER SYSTEM INSTALLATION
A COENCELED SLIM DUCTED MINI SPLIT FUJITSU
Просмотров 6 тыс.3 года назад
A COENCELED SLIM DUCTED MINI SPLIT FUJITSU
CENTRAL AIR CONDITIONING INSTALLATION 16 SEER
Просмотров 803 года назад
CENTRAL AIR CONDITIONING INSTALLATION 16 SEER
3 piece bathroom in the basement
Просмотров 203 года назад
3 piece bathroom in the basement

Комментарии

  • @ryebread8953
    @ryebread8953 2 месяца назад

    Looks good for my phone...!

  • @steveo6034
    @steveo6034 4 месяца назад

    What happens if theres a leak down the road?

  • @maintenanceman1015
    @maintenanceman1015 5 месяцев назад

    Saw the electric heater but no drain on that line.

  • @TH3huntz354
    @TH3huntz354 5 месяцев назад

    Why reduce to 1.5 then back to 2 again

    • @Comanchee0689
      @Comanchee0689 5 месяцев назад

      It doesn't, it's a 2" T with a 2"x1½" copper nipple into the backflow. Then 1½" all the way out to the wall.

  • @John_Lee_
    @John_Lee_ 6 месяцев назад

    Is that a domestic expansion tank on the heating system?

  • @John_Lee_
    @John_Lee_ 6 месяцев назад

    suffolk, ny

  • @landmark4609
    @landmark4609 6 месяцев назад

    This is good, at least 6"to 10 "above the sub floor no nails or screws below 6"

  • @Ravensun807
    @Ravensun807 7 месяцев назад

    I like the idea. But questions about this system. What happens in the event that somewhere in the pipe tubes leaks a hole or gets busted. What are the implications of repair done? Would be as easy as removing a section of the tube? Or does it require to replace the whole band of tubes ?

    • @michaellewis4632
      @michaellewis4632 7 месяцев назад

      Probably just as bad as a pipe bursting in your home except you just won’t know intill you either fall threw the floor or your water bill is sky high

  • @rickyleight939
    @rickyleight939 7 месяцев назад

    Does it get regular heating to of some sort ? Radiator, boiler , heat pump, etc ? Curious if jus that alone is eniguh to keeep the house warm and keep it from freezing the pipes

    • @steveo6034
      @steveo6034 4 месяца назад

      Oh yeah that water gets circulated thru a boiler

  • @weareham3068
    @weareham3068 8 месяцев назад

    Where’s the filter? Looks good

  • @coreym5072
    @coreym5072 10 месяцев назад

    What material did you use?

    • @christopherheating2965
      @christopherheating2965 10 месяцев назад

      Radiant heat tubing 1/2 inche 300 feet per loop

    • @coreym5072
      @coreym5072 10 месяцев назад

      @@christopherheating2965 I know that. What is it stapled to?

    • @christopherheating2965
      @christopherheating2965 10 месяцев назад

      @@coreym5072 PEX Tube Talons Twin Talon for 1/2" & 5/8" & 3/4" PEX Tubing

  • @metalmassacre84
    @metalmassacre84 10 месяцев назад

    Does the liner need to be installed if its on concrete slab? (First floor)

    • @christopherheating2965
      @christopherheating2965 10 месяцев назад

      No

    • @metalmassacre84
      @metalmassacre84 10 месяцев назад

      @@christopherheating2965 thanks. All the videos ive seen were on plywood but nothing on concrete floors.

    • @lancesmith6864
      @lancesmith6864 8 месяцев назад

      @@metalmassacre84for concrete you’ll put thunder down, then your pan. Step on pan and work air out/secure bond. Let dry for 30-45 minutes. Thinset around drain hole, install drain. Last you’ll apply membrane to the edges (wall meets shower, floor meets curb, top of curb.) allow time to dry, then lazer your tiles and install.

    • @Botosucka911
      @Botosucka911 2 месяца назад

      For concrete you put thunder down??? What does thunder mean?

  • @kennethaguilar2343
    @kennethaguilar2343 11 месяцев назад

    What do you do after that?

    • @John_Lee_
      @John_Lee_ 6 месяцев назад

      put down the mud and tile and put the cement walls in

  • @cxsey8587
    @cxsey8587 Год назад

    When you’re pushing into the corners with the screwdriver are you not worried about damaging the membrane ?

  • @davidamezquita7098
    @davidamezquita7098 Год назад

    Do you pour your motar with the slope prior to that in the wood subfloor or you do you just put the plastic straight on the plywood

  • @josepacheco-hj6jl
    @josepacheco-hj6jl Год назад

    Q pegamento usas Para unirlo? gracias

  • @joseluisponcehermosilla6064
    @joseluisponcehermosilla6064 Год назад

    ????? Se ve bien

  • @joseluisponcehermosilla6064
    @joseluisponcehermosilla6064 Год назад

    Cuál es el costo de ese trabajo

  • @TheMrBrandonlewis
    @TheMrBrandonlewis Год назад

    No drip leg bro?

  • @Keegeth
    @Keegeth Год назад

    Piping is on point but that white box in the middle that says navien on it 🤮 im so sick of getting service calls for those and running into cross contamination.

  • @irq001
    @irq001 Год назад

    I have a 1500 sq ft 1st floor - 1 master bed + bath, 2 smaller bed rooms, 1 small bath and a large loft. Currently, it is served by an aging gas furnace + AC. The return is one single grill in the hall way. Master Bed and loft has two supply registers and rest are one register each. My guess is that I will need 36K BTU heat pump for this. Can one or two such slim duct Fujitsu serve this floor ? Since the opening to attic is too small ( attic itself is big ) to take up a full size air handler, I am considering this slim duct option . Another constraint is that only vertical mount option is feasible for supply registers in master bed and loft, as the roof is slanting cathedral type with no attic space there. Attic is available for rest of the rooms , bath and hallway. I guess these slim duct AH can be vertically mounted too .

    • @christopherheating2965
      @christopherheating2965 Год назад

      36000 btu slim ducted will work fine , have in mind that you can put 4 supplies and one return

  • @lobsterstrange
    @lobsterstrange Год назад

    So after that your gonna pour concrete?

  • @outlawpete4636
    @outlawpete4636 Год назад

    It looks like someone unleashed a metalic monster in that customers attic🤣

  • @karmendimas5274
    @karmendimas5274 Год назад

    what was the TOTAL cost of the system install including cost of equipment,, the grand total?

    • @christopherheating2965
      @christopherheating2965 Год назад

      $15000 total

    • @karmendimas5274
      @karmendimas5274 Год назад

      @@christopherheating2965 thanks for the insight, ouch! lol, just had a goodman heatpump put in for a grand total of $6200, you paid 3x as much,, i was thinking about going with the ducted minisplit, are they more efficient?

  • @seanmcnally1132
    @seanmcnally1132 2 года назад

    Where is the navi clean or the magna clean on the return side for the cast iron on the hydronic piping

    • @christopherheating2965
      @christopherheating2965 2 года назад

      I PUT A FILTER ON THE COLD WATER SUPPLY LINE FOR THAT

    • @seanmcnally1132
      @seanmcnally1132 2 года назад

      @@christopherheating2965 wrong answer bud, the Navi clean and magma clean are supposed to be on the hydronic side, it’s a magnetic filter to catch all of the iron oxides, has nothing to do with cold water piping

    • @christopherheating2965
      @christopherheating2965 2 года назад

      @@seanmcnally1132 explain that to my inspector that passed my inspection