Clean Air Heating & Cooling
Clean Air Heating & Cooling
  • Видео 134
  • Просмотров 979 471

Видео

Fall storm day in Bellingham WA. Rain going sideways. 🌧️ 🌬️
Просмотров 1123 месяца назад
Fall storm day in Bellingham WA. Rain going sideways. 🌧️ 🌬️
Now is a good time to get your new furnace or air conditioner installed.
Просмотров 573 месяца назад
Now is a good time to get your new furnace or air conditioner installed.
Next day furnace replacement. LP 80% with filter.
Просмотров 3193 месяца назад
Next day furnace replacement. LP 80% with filter.
Electric vs Gas fireplace. What are the differences?
Просмотров 1843 месяца назад
Electric vs Gas fireplace. What are the differences?
Fall Furnace installation deals! 🔥💸💰🏡🏘️
Просмотров 2,7 тыс.5 месяцев назад
Beat the rush before it gets cold. Let us help you get the furnace or heat pump you need before it gets too cold. Call is the best time to purchase a furnace or heat oil and we have deals in place to help you do just that. Call or text me 360-398-9400
Water heater leak, or something else?
Просмотров 2,3 тыс.6 месяцев назад
Water heater leak, or something else?
How to collect and enter refrigerant line set into Mitsubishi Diamond System Builder
Просмотров 1307 месяцев назад
How to collect and enter refrigerant line set into Mitsubishi Diamond System Builder
How to use the thermostat remote for Mitsubishi GS heat pump
Просмотров 2,9 тыс.7 месяцев назад
Guys, thank you for coming here to watch this. Please let me know in the comments if you want additional details or anything specific and do my best to upload a new video with that information soon.
Removing an oil and wood furnace and installing a Mitsubishi heat pump with Lennox 99% eff furnace.
Просмотров 1757 месяцев назад
Removing an oil and wood furnace and installing a Mitsubishi heat pump with Lennox 99% eff furnace.
How to prevent refrigerant leaks in Air Conditioning coil and Heat Pump. TXV, Distributor, Bulb,
Просмотров 9728 месяцев назад
How to prevent refrigerant leaks in Air Conditioning coil and Heat Pump. TXV, Distributor, Bulb,
Team Spotlight: Clean Air Heating & Cooling
Просмотров 1,7 тыс.Год назад
Team Spotlight: Clean Air Heating & Cooling
Mini split wiring, for electricians. From a service tech.
Просмотров 312Год назад
Mini split wiring, for electricians. From a service tech.
Boiler fittings - shrinkflation. Brass PEX fittings for hydronic boiler replacements.
Просмотров 128Год назад
Boiler fittings - shrinkflation. Brass PEX fittings for hydronic boiler replacements.
How to Glue PVC Pipe. AVOID weak joints and leaks.
Просмотров 1 тыс.Год назад
How to Glue PVC Pipe. AVOID weak joints and leaks.
Bellingham, WA | Clean Air Heating & Cooling
Просмотров 53Год назад
Bellingham, WA | Clean Air Heating & Cooling
Furnace inducer motor blown apart. HVAC service call.
Просмотров 139Год назад
Furnace inducer motor blown apart. HVAC service call.
Update: Electronic Air Cleaner (AKA: electrostatic air filter) Proper Cleaning
Просмотров 622Год назад
Update: Electronic Air Cleaner (AKA: electrostatic air filter) Proper Cleaning
How to replace the blower fan wheel in the a ductless mini split heat pump.
Просмотров 8 тыс.Год назад
How to replace the blower fan wheel in the a ductless mini split heat pump.
Tankless Heat Exchanger Failure. Navien Water leak service call.
Просмотров 5 тыс.Год назад
Tankless Heat Exchanger Failure. Navien Water leak service call.
DIY boiler replacement. Upgrading Zone control, Pumps & Piping for in floor radiant heat.
Просмотров 386Год назад
DIY boiler replacement. Upgrading Zone control, Pumps & Piping for in floor radiant heat.
Client Testimonial | Sleep Better with Clean Air
Просмотров 11Год назад
Client Testimonial | Sleep Better with Clean Air
Client Testimonials | Don't Wait for "What If"
Просмотров 12Год назад
Client Testimonials | Don't Wait for "What If"
Client Testimonial | What we were able to do for Lakeside Gardens Adult Family Home
Просмотров 9Год назад
Client Testimonial | What we were able to do for Lakeside Gardens Adult Family Home
Instant Hot Water Recirculation Loop. Tank or Tankless Water Heaters
Просмотров 7 тыс.Год назад
Instant Hot Water Recirculation Loop. Tank or Tankless Water Heaters
Lennox Variable Heat Pump - How Quiet is it?
Просмотров 1,3 тыс.Год назад
Lennox Variable Heat Pump - How Quiet is it?
HVAC service at midnight. Gas valve repair on natural gas furnace.
Просмотров 58Год назад
HVAC service at midnight. Gas valve repair on natural gas furnace.
Before you buy your next furnace, mini split heat pump or air conditioner, consider service.
Просмотров 68Год назад
Before you buy your next furnace, mini split heat pump or air conditioner, consider service.
HVAC Installer - Randi
Просмотров 210Год назад
HVAC Installer - Randi
HVAC manager shares her career grouth at Clean Air
Просмотров 44Год назад
HVAC manager shares her career grouth at Clean Air

Комментарии

  • @jonpostman5524
    @jonpostman5524 6 дней назад

    Hi I have a navien NR - 210A just had the error code 10E come up on my machine this morning. Vent filters are all clean so I left for work with the water heater not working. When I got home water was leaking from the unit. Any thoughts what this could be?

    • @SuperSir1234
      @SuperSir1234 12 часов назад

      were you able to fix this - I may have the same issue when someone takes a very long shower

  • @jonathanbrooks4782
    @jonathanbrooks4782 14 дней назад

    I am looking forward to using this method, have some uninsulated duct work in a crawl space. Hopefully, this will help with energy conservation.

  • @sonickchri
    @sonickchri 20 дней назад

    Thank you for the demonstration. I have a manufactured home crossover that I am considering replacing. On the existing flex duct It says 10" with R-Value rating 5.6. It is only 10 ft-long but I see replacements only come in minimum 25' length. If you were me, would you replace the crossover with a rigid duct? I think I have noticed that the airflow on that half of the house seems quite a bit less than the other side (the side with the indoor air handler unit, of course). I am also in Washington State. Thanks for any and all advice!

  • @akbychoice
    @akbychoice 20 дней назад

    There are different T5 thermostats they don’t all setup the same way.

  • @kylek244
    @kylek244 28 дней назад

    Anchorage AK here, on Municipality water, 2017 installed. New internal pumps in 2023. Now new board and heat exchanger in 2025.

  • @kurtfalkowski6441
    @kurtfalkowski6441 Месяц назад

    Thank you, learned a lot!

  • @holly7010
    @holly7010 Месяц назад

    Please do one on setting the heat properly I bought my tiny house used and there is no manual. I can't find a video on setting the heat only air..... no matter what I do it barely heats up and the fan barely blows. a repair man said there's nothing wrong with the unit,,,,, I'M COLD I have to stand less than 4 feet from the unit to feel the heat blowing out but the rest of the 400 ft house feels cold, I slept last night with 4 blankets, socks etc. on. PLEASE HELP me learn how to set it correctly

  • @jcepri
    @jcepri Месяц назад

    I have an 1174 zf ranch. I just got a quote for one oc these systems with 3 wall units. $25,000. They are out of their minds.

  • @JackieCurrie-r5u
    @JackieCurrie-r5u Месяц назад

    I have the same question as someone else…is there anyway to know the current temp that it’s reading at? I understand it measures temp on the unit not the remote, but I’d like to know what temp it’s currently reading at not just what I’m setting it for.

  • @heatherb6348
    @heatherb6348 Месяц назад

    If you’d be quiet for a minute I could hear it

  • @wendygarey7925
    @wendygarey7925 Месяц назад

    I need to know how the best works ..only right now

  • @cakr8818
    @cakr8818 Месяц назад

    Thank you for this! I live in Oregon. Can you make another video to go over the black section of the remote that goes controls timers and settings for different times of the day? I'm confused by the options. It doesn't appear to have the same functions. Thank you so much!

  • @mikeysan01
    @mikeysan01 Месяц назад

    Very informative!

  • @arfr3567
    @arfr3567 Месяц назад

    Very informative. Dig a trench. would never think about that.

  • @lueannabracha2472
    @lueannabracha2472 Месяц назад

    Think you may have convinced me. I am in MT and we have a boiler system from the 70s and no AC. The previous owner had the brilliant idea of extending the boiler system to the garage, so nothing is ever really warm. We have been thinking about putting in a heating system but having to cut wood floors and tile floors for the ducting system has kept us second guessing it. I think I may reach out to a local agency to get a price idea.

  • @QDADHDPTSDRN
    @QDADHDPTSDRN Месяц назад

    are you supposed to insulate the white pvc type pipes too? (or if it's not required, is there benefit to it anyway? or any safety issues or downsides to NOT doing that?)

  • @sonalalji5653
    @sonalalji5653 2 месяца назад

    I have moisture in my basement above my ceiling tile. I'm trying to insulate my ducks to prevent condensation. Is it okay if I just insulate the runs? And not worry about the elbow joints coming into the run?

  • @jo2522
    @jo2522 2 месяца назад

    I have some rigid duct that is up against the ceiling so i cant get behind it too easily and using a wrap is just practical. Is there an insulating paint i could brush on to help insulate my galvanized rigid duct?

  • @DerekWC
    @DerekWC 2 месяца назад

    Why is it unhealthy to have a home at a temp of 59 degrees???

  • @DerekWC
    @DerekWC 2 месяца назад

    Ok so how do I turn it on???😂😂

  • @cindysmith3753
    @cindysmith3753 2 месяца назад

    Why so wide a trench?

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 Месяц назад

      @@cindysmith3753 so we can work inside of it safely and be able to lay the pipe down inside of the conduit and backfill it with soft soil first before leaking it back in. We hired an exhibition company to do this part and that's the bucket size they had on their excavator. I don't think the price would have been any different. I imagine you could do it with a ditch witch

  • @randyswenson5334
    @randyswenson5334 2 месяца назад

    Excellent video but did he ever mention what "the product" was he used for cleaning? Thanks.

  • @moy6569
    @moy6569 2 месяца назад

    Awesome, you are truly dedicated.

  • @lifeofasapp
    @lifeofasapp 2 месяца назад

    Can you use Duct tape instead of the foil tape?

  • @RingoRoseman
    @RingoRoseman 2 месяца назад

    Is there a way to see what temperature the thermostat is reading? The remote only shows what you have it set to.

  • @Iknewit6
    @Iknewit6 2 месяца назад

    Get some proper gloves, tetanus is a killer

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 2 месяца назад

      @@Iknewit6 honestly, I didn't notice that until half way through the video. 🤦‍♂️

  • @Kayak51
    @Kayak51 2 месяца назад

    This is quiet.

  • @kaynagel-wisberger1940
    @kaynagel-wisberger1940 2 месяца назад

    Can u run a recirculating hot water system with thermostat off of single line garden hose. Single line has both hot and cold water lines into it

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 2 месяца назад

      @@kaynagel-wisberger1940 can you give me more context? Are you trying to have instant hot water at the garden hose?

  • @potatochipz3097
    @potatochipz3097 3 месяца назад

    Great video. How do you change the remote setting to Celsius ?

  • @leecunningham5867
    @leecunningham5867 3 месяца назад

    This is hard to watch 😂😂

    • @NaN0Stupid13
      @NaN0Stupid13 2 месяца назад

      wack wrapping was hard to watch to 🤣

  • @MultiRugman
    @MultiRugman 3 месяца назад

    I have some old duct in my addict , i saw some disconnection and with aluminum foil I seal them . I decided to do the installation on all my ducts myself What material to use? Thank you

    • @maplecity9829
      @maplecity9829 3 месяца назад

      It's spelled attic, you stable genius.

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 2 месяца назад

      @@MultiRugman foil insulation is good. You can also use fiberglass. R8 is the standard but you can always do extra.

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 2 месяца назад

      @@maplecity9829 no worries. We figured it out. 😃👍

  • @ToddCoston
    @ToddCoston 3 месяца назад

    We have 9 total mini splits in our house (we have 2 outdoor units to handle them). We are so happy with them...EXCEPT...2 of the mini splits are the ceiling mounted - which is in 2 upstairs bedrooms. There are no issues with the cooling feature, but the heat feature has given us problems for 3 winters now. No matter how low you set the heat temperature on the wall thermostat, the actual temperature in the room just continues to rise. It's a huge problem when we have guests. We have the heat set at 68 degrees, but after about an hour or so, the actual temperature rises to over 80 degrees. Then we have to just turn the unit off. Our installers have spent hours trying to figure it out, to no avail. Do you have any suggestions???

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 3 месяца назад

      @@ToddCoston absolutely. Thank you for asking this is actually a very common problem with multi-zone design. If you can give me more information about the size of those two units how many BTUs they are and the rest of the indoor units connected to the same system then I need to know the model number of the outdoor unit that services all of these then I can get you some answers.

  • @buenafedeleon1346
    @buenafedeleon1346 3 месяца назад

    i have a hybrid split system and uses honeywell, will it be a 2 for the cooling stage? my previous thermostat broke and i replaced with an older version since it is cheaper. now it's blowing hot air with cool on. I dont know the model of the thermostat before bc i threw it away :/

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 3 месяца назад

      @@buenafedeleon1346 it depends if you have a two-stage compressor. Do you know if your heat pump or AC is a two stage or a single stage?

  • @annemariedebarros2475
    @annemariedebarros2475 3 месяца назад

    I have rectangular duct in my garage supplying heat to the bedrooms above. It has this old fiberglass insulation that falling off. The duct is flushed to the ceiling. How should insulate? Should I use the same material with the spacer for higher R value? Thanks

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 3 месяца назад

      @@annemariedebarros2475 either type of insulation would be a good choice. I prefer the foil type because it's easier to use and it isn't irritating to the skin.

  • @ERNESTOVARGAS-i9m
    @ERNESTOVARGAS-i9m 3 месяца назад

    how do turn off thermostat option, i want it to continue working without shutting off

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 3 месяца назад

      @@ERNESTOVARGAS-i9m that is not possible. Please don't do that. It's bad for the unit.

  • @gabrielac.206
    @gabrielac.206 3 месяца назад

    Thanks

  • @mark.r8900
    @mark.r8900 3 месяца назад

    Great video. I have a forced air gas furnace used only for heating. Also have and air handler with outdoor condenser used only for cooling. Do I have a dual fuel system? Thanks

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 3 месяца назад

      @@mark.r8900 A dual fuel system is a gas furnace with heat pump, using the same ductwork.

  • @RILXY
    @RILXY 3 месяца назад

    Wrap the pipe first before you hang them. Then when it’s installed with the elbows you would only need to wrap the elbows. Helps me go a little quicker

  • @CHarris73
    @CHarris73 3 месяца назад

    I have the t4 pro series and it continues to blow hot air on cool auto , how do I get the heat pump to blow cold

  • @KegEdits1
    @KegEdits1 4 месяца назад

    Hey guys are you looking to turn your RUclips viewers into sales/jobs?

  • @LouisRodriguez-x2y
    @LouisRodriguez-x2y 4 месяца назад

    I have a carrier unit but I cannot get the outdoor unit to turn on. Where should I have the reverse valve set to o or b

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 4 месяца назад

      @@LouisRodriguez-x2y it depends. You have to look in the manual for the heat pump. It will tell you how to set it. If I remember correctly, Carrier is B.

  • @kevinduffy972
    @kevinduffy972 4 месяца назад

    What brand of tape are you using?

  • @pjcorwin504
    @pjcorwin504 4 месяца назад

    Thank you so much!

  • @salimoneus
    @salimoneus 4 месяца назад

    "in the winter, the outdoor unit will pull warm air from the outside and send it to the indoor unit" wait, what? warm winter air? what are ya smokin fella...

  • @richinoregon
    @richinoregon 4 месяца назад

    I encountered these systems when I was in Cambodia, and I HATED them. They are DRAFTY. If you home currently has only baseboard heating, I and you want to save money, then they are good. However, in the long run, going whole hog putting in ductwork, installing a GAS furnace and a standard AC system will save you money, which is what I did 15 years ago, and I thank God I did. Natural Gas is 1/3 to 1/4 the cost per BTU than electricity to heat. My winter utility bill would be $200 more a month during the winter if I used a heat pump (which is what a mini-split systems are).

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 4 месяца назад

      @@richinoregon you are making an excellent point! I think from watching utilities in different areas of the country and different states or even different countries across the world the recommendation might vary based on more unique markets where the cost of energy varies by a lot. It's always good to do a good energy evaluation prior to purchasing these to make sure that it makes sense. There's other benefits other than savings so there's a lot of things to consider when deciding what system to get.

    • @richinoregon
      @richinoregon 4 месяца назад

      @@cleanairheatingcooling4105 Here is another consideration. If you live in the desert southwest, AC may not be the best choice--an evaporative cooler may be. I lived for 4 years in Nevada and had an evaporative cooler (swamp cooler) for cooling, and they could get COLD. The outside air temperature would be over 100 deg F during the day (I was in the high desert) but the temperature of the air coming out of the ductwork was 47 deg F. The only power they consume is to run the fan.

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 4 месяца назад

      @@richinoregon that's right. In the dry areas those work well!

  • @benjaminmartin7702
    @benjaminmartin7702 4 месяца назад

    I thought you use the spacer so the pipes doesn’t sweat.

  • @jaredzanelli7867
    @jaredzanelli7867 4 месяца назад

    Do you have to remove the hanging straps and insulate below them then reinstall?

    • @cleanairheatingcooling4105
      @cleanairheatingcooling4105 4 месяца назад

      @@jaredzanelli7867 you don't have to. If you do so the hanging straps will crash the insulation that's reducing the auto value just below the strap. It's better to insulate around the strap as shown in the video.

  • @Jame-eq4hd
    @Jame-eq4hd 5 месяцев назад

    What is the difference between the models A1013A, A1013P, A1013Q, A1013U and A1013T?

  • @fourolives142
    @fourolives142 5 месяцев назад

    Thank you for this straight to the point informational video! Can you tell me what cleaner you are using?