PVT-PILOT
PVT-PILOT
  • Видео 9
  • Просмотров 533 967

Видео

ICON A5 on Lake HoustonICON A5 on Lake Houston
ICON A5 on Lake Houston
Просмотров 944 месяца назад
Light Sport Aircraft - LSA Foldable wings Amphibious Audio Clip Credit to Kenny Loggins - Danger Zone (Top Gun Soundtrack)
2012 Polaris Ranger 800XP 3597 3 Check Engine code error light How To DIY2012 Polaris Ranger 800XP 3597 3 Check Engine code error light How To DIY
2012 Polaris Ranger 800XP 3597 3 Check Engine code error light How To DIY
Просмотров 2216 месяцев назад
2012 Polaris Ranger 800XP 3597 3 Check Engine code error light
Pentair Mastertemp 400 Replacement of ThermistorPentair Mastertemp 400 Replacement of Thermistor
Pentair Mastertemp 400 Replacement of Thermistor
Просмотров 72 тыс.5 лет назад
Thermistor Part #: 42001-00536S HLS (High Limit Switch) Part #: 42001-0063S
Pentair Mastertemp 400 Heat Coil Tube Sheet Assembly ReplacementPentair Mastertemp 400 Heat Coil Tube Sheet Assembly Replacement
Pentair Mastertemp 400 Heat Coil Tube Sheet Assembly Replacement
Просмотров 47 тыс.5 лет назад
Part #: 77707-0234
Thermal Regulator Replacement on Pentair Mastertemp 400 Pool/Spa HeaterThermal Regulator Replacement on Pentair Mastertemp 400 Pool/Spa Heater
Thermal Regulator Replacement on Pentair Mastertemp 400 Pool/Spa Heater
Просмотров 69 тыс.5 лет назад
Replacement of Thermal Regulator on Mastertemp 400 Pool/Spa Heater Part #: 38000-0007S (Thermal Regulator Only) Part #: 77707-0010 (Thermal Regulator w/spring, black cap and O-Ring) Lonesome Avenue by The 126ers Creative Commons - Attribution 3.0 Unported- CC BY 3.0 creativecommons.org/licenses/... Music provided by FreeMusic109 ruclips.net/user/FreeMusic109
PENTAIR MASTERTEMP 400 ERROR LIGHT LED EXPLAINEDPENTAIR MASTERTEMP 400 ERROR LIGHT LED EXPLAINED
PENTAIR MASTERTEMP 400 ERROR LIGHT LED EXPLAINED
Просмотров 111 тыс.6 лет назад
WHAT DO THE ERROR LIGHTS/LEDS MEAN ON THE BACK OF THE CONTROL BOARD? IDENTIFY EXPLAIN DIAGNOSE DIAGNOSTIC PS HLS AFS AGS SFS E01 E05 WATER PRESSURE SWITCH 42001-0060S HIGH LIMIT SWITCH 135°F 42001-0063S MANIFOLD BYPASS VALVE KIT 77707-0001 VALVE STEP BYPASS ONLY 42001-0014Z THERMISTOR 42001-0053S AIR FLOW SWITCH 42001-0061S TUBE SHEET COIL ASSEMBLY (HEATING COILS) 77707-0234 GAS SHUTOFF 140°F 4...
PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIRPENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIR
PENTAIR MASTERTEMP 400 POOL/SPA HEATER AFS AIR FLOW SWITCH ERROR LIGHT REPAIR
Просмотров 156 тыс.6 лет назад
TROUBLESHOOTING OF AFS ERROR LIGHT LEADS ME TO FIND A COMPLETELY DIFFERENT AND MUCH MORE COMPLICATED AND EXPENSIVE ISSUE. DON'T ASSUME YOU HAVE A DEFECTIVE AFS (AIR FLOW SWITCH) IF YOU HAVE AFS ERROR LIGHT. IT IS A VERY SIMPLE COMPONENT OF THE HEATER, SO THERE IS NOT REALLY MUCH THAT CAN GO WRONG WITH IT. JUST TEST ITS FUNCTIONALITY FIRST BEFORE ORDERING ONE. YOU WILL MOST LIKELY SAVE YOURSELF ...
Pentair Master Temp 400 Pool and Spa Heater HLS Error Light Repair Replace Manifold Bypass ValvePentair Master Temp 400 Pool and Spa Heater HLS Error Light Repair Replace Manifold Bypass Valve
Pentair Master Temp 400 Pool and Spa Heater HLS Error Light Repair Replace Manifold Bypass Valve
Просмотров 77 тыс.7 лет назад
Pentair Master Temp 400 - got an HLS error light on the back of the gel touch circuit board of the heater control panel. This video shows the removal and disassembly of the Sta-Rite manifold attached to the side of the boiler. I ended up replacing the Manifold Bypass Valve instead of the suspected HLS (High Limit Switch) to clear the error. Part number of Manifold Bypass Valve is 42001-0014 Par...

Комментарии

  • @furiousgtz
    @furiousgtz Месяц назад

    Pentair mastertemp 400 showing E2. Is this the solution?

  • @JohnSmith-yc7jv
    @JohnSmith-yc7jv Месяц назад

    I'm a retired contractor so pool equipment is new to me. The "no-clue" sensor you hooked up is the AGS, I think. You mentioned the ignitor sparks out at the end of it, but it's a glow type ignitor with no spark. Additionally, the ignitor serves as the flame sensor too. That was quite a frustrating and difficult diagnosis, but I tip my hat to any tech with your kind of patience. Good video, man. I have a friend whose Pentair 250 is down, so even though it's a Sunday I'm going to test sensors and thermal regulator. I don't use a parts cannon and 2 service companies (that replaced a part and didn't stay on it to get it fixed) has got me accepting it as a challenge. I'll bet I can diagnose it tomorrow. Tons of vids online.

  • @AndySchneider-l2k
    @AndySchneider-l2k Месяц назад

    Outstanding video!! And VERY helpful! This is exactly what happened to mine, including the rattling. Your video makes it immensely easier for me to fix it myself!

  • @JohnSmith-yc7jv
    @JohnSmith-yc7jv Месяц назад

    Thank you for this. For the diagnostic tech, that's an easy ten minute test to do, rather than blindly order a new one and hope it fixes it.

  • @billshaker9961
    @billshaker9961 Месяц назад

    Can you show the best way to mount the thermal regulator on the spring?

  • @johncappel7143
    @johncappel7143 2 месяца назад

    This unit is garbage. Have a newer one just under four years old…new pool. Hardly use it and it’s had nothing but problems. As I type it it’s had two repairs and the light is back on and not working. Garbage

  • @grapplerguy2007
    @grapplerguy2007 2 месяца назад

    We've changed the hls thermistor flue stack sensor bypass and still get a service once hits 89 degrees.

  • @bharned3
    @bharned3 2 месяца назад

    Thanks again for another great video.

  • @xmas4203
    @xmas4203 2 месяца назад

    I've done the coil tubes on the mastertemp many times. It's always due to chemical damage. Low pH in fiberglass spas and inline chlorinators are a recipe for disaster.

  • @xmas4203
    @xmas4203 2 месяца назад

    I'm a pool repair guy. That inline chlorinator is probably what ate up the copper tubes because it sits higher than the manifold and drains down acidic water when the pump is off. Good trouble shooting.

  • @deebo2808
    @deebo2808 3 месяца назад

    Awesome video! And a great job videoing and working with 1 hand

  • @itsmebran3805
    @itsmebran3805 3 месяца назад

    Salt systems in pools will constantly ruin this part. Salt pools= good for humans. BAD for pool equipment and plaster.

  • @michaelwebster6448
    @michaelwebster6448 4 месяца назад

    I want one

  • @romanjimenez471
    @romanjimenez471 4 месяца назад

    New heater

  • @saadyzuleyman7138
    @saadyzuleyman7138 4 месяца назад

    Excelente!

    • @pvt-pilot
      @pvt-pilot 4 месяца назад

      @@saadyzuleyman7138 Gracias!

  • @tincash406
    @tincash406 4 месяца назад

    I am having the same issue currently, however I have no rust inside my header. I took the bottom bolt of the manifold off and the water drained and was very clear. I plan to open it up to see if maybe its one of the seals on the manifold or if I need to replace the entire heater coil. Thanks for the video!

  • @justicestaines9238
    @justicestaines9238 4 месяца назад

    What a nightmare. I’m going to give this a try tomorrow

  • @BLUESGUITAROCKER
    @BLUESGUITAROCKER 5 месяцев назад

    Mine turns on with heater light flashing . Heater fires then goes off . AAFS ERROR

  • @irmaperez6327
    @irmaperez6327 5 месяцев назад

    So i changed mine out and now its leaking water can the manifold be damaged

  • @irmaperez6327
    @irmaperez6327 5 месяцев назад

    Hello do you have to add lubricant to the plug

  • @goreyboggs
    @goreyboggs 6 месяцев назад

    Mine showing 115 has only about 80°. I ordered it hopefully have it in tomorrow.

    • @pvt-pilot
      @pvt-pilot 6 месяцев назад

      You are certainly on the right track. High resistance readings on thermistor translates to high temperature readings by control board. Any higher resistance than this, the contol board will see it as a full open (infinite resistance) and result in E01 error. Also, make sure you spade connectors are clean and not corroded so that you have zero resistance across each connector. You don't want something like corrosion to add resistance into the equation while trying to get an accurate reading from a resistance based component such as a thermistor. Cheers!

  • @Abortiz12
    @Abortiz12 6 месяцев назад

    Thanks for that video. It was very informative.

  • @rleader1
    @rleader1 6 месяцев назад

    Hey. My Heater runs fine for a while but then shuts off and I get a service heater light. No error codes. I checked the backside of the panel and no lights were lit. I believe it cycles back on again eventually, but I'm not sure. If I shut it down though it will fire back up and heat again but eventually stops. Any suggestions? Is it likely the part in this video? Thanks!

  • @kenscott1082
    @kenscott1082 6 месяцев назад

    Cool video

  • @moltenpros
    @moltenpros 7 месяцев назад

    What heated water is coming out luke warm and it never heats the pool

  • @bills1995vette
    @bills1995vette 7 месяцев назад

    Pentair sucks.

  • @Cath5712
    @Cath5712 7 месяцев назад

    Amazing video. thank you

  • @FlyfishNH
    @FlyfishNH 7 месяцев назад

    Be aware that an airflow error may have absolutely nothing to do with airflow in any way. Mine showed an air flow error light and ‘service heater’ light. But nothing turned on at all. No blower. The machine can’t even sense an air flow error unless the blower is running because there’s no suction at the intake to activate the air flow switch until the blower actually turns on. So it didn’t make sense to me. Ultimately, the red wire to the blower motor was disconnected from its connection at the board. Reconnecting that solved all problems. All the info in this amazing video helped me trouble shoot it!

  • @ArmPump
    @ArmPump 7 месяцев назад

    Not to be critical BUT the visegrips were on the gas pipe union backwards and no need for Teflon on the union threads as the threads are not the sealing surfaces. Looks good! 👍

  • @MRBIGDG1
    @MRBIGDG1 7 месяцев назад

    How old was that exchanger?

  • @daskrak6979
    @daskrak6979 8 месяцев назад

    Excellent and very informative video, thank you! I manage a property with 4 Mastertemp 400 heaters and I hate them. The old black capsule style ones seemed to be much better quality and last longer. These are not lasting us more than a couple of years, although it's due to being on the Florida coast. My main problem is the control boards get corrosion on them extremely fast and need replacing. I'm now replacing them all with Raypak heaters with the easily replaceable "ProTek Shield" anode to battle corrosion and they just seem far superior in my experience thus far. Thanks again for taking the time to do this!

  • @Hoffyrevhead
    @Hoffyrevhead 8 месяцев назад

    Mine is stuck in that hole behind a black tab on the upper part. What solution to get that out

  • @cngautos
    @cngautos 8 месяцев назад

    Thanks for your video

  • @stevengregoryphotography
    @stevengregoryphotography 8 месяцев назад

    My coil won’t fit if I place first place the insulation soft insulation blanket on the bottom of the combustion chamber followed by the hard insulation board with the notch cut out over the lip of the combustion chamber. I see how this creates a perfect fit and how the hard insulation board then butts up flush against the face of the combustion chamber, but in my case, then the coil does not fit into that recessed area for it to align with the bolt holes for the manifold. If I pull the insulation and way and off that lip so that no insulation is taking up space in that recessed area of the combustion chamber, only then will the coil fit and align with the bolts with me having maybe 1/8” of play. Can you confirm you did in fact place the insulation on top of that lip in the combustion chamber per your note, vs having left it off in the video footage you shot? Thank you and others for any advice!

  • @victorfong322
    @victorfong322 9 месяцев назад

    Thanks for this video. Even 5 years later, it helped me fix my own heater. It was completed stuffed with leaves and debris brought in by rats. After cleaning, the error lights would only come on one at a time. After fixing the E6 error by replacing the flu sensor, the PS light came on. After fixing that, the HLS light came on. After replacing that, the AFS light came on. Once I replaced the Air flow switch, the unit finally cleared and the fan and heater came on.

    • @pvt-pilot
      @pvt-pilot 9 месяцев назад

      That's intense, but you stuck through it. Nice job!

  • @jimfeilbach3234
    @jimfeilbach3234 9 месяцев назад

    Thanks!

  • @ystebadvonschlegel3295
    @ystebadvonschlegel3295 11 месяцев назад

    Wonderful video - just fixed mine and back in business. There are a lot of rusty bolts and corrosion in side the unit - not sure if I should be doing something or spraying something in there to help maintain. Definitely doesn't look like they used stainless parts. Also my HLS was filled inside with what looks like calcium deposits - does that mean I've got something wrong in my pool chemistry or is that a normal development over time? Thank you!!

    • @pvt-pilot
      @pvt-pilot 11 месяцев назад

      Yes, bad chemistry, but nobody keeps it perfect all the time. Calcium build-up happens. No shame, just roll with it (replace parts, clean tiles, all the fun stuff)

  • @MarkHerzog-h3z
    @MarkHerzog-h3z 11 месяцев назад

    Thank you for this! Great video!

  • @kernalrom
    @kernalrom Год назад

    Same happened to me. thanks for the video

  • @centinnel
    @centinnel Год назад

    Awesome 👏 just called

  • @shahryarfarhang200
    @shahryarfarhang200 Год назад

  • @stevemclaughlin4713
    @stevemclaughlin4713 Год назад

    Awesome video and great instruction on the replacement of the internal bypass valve which cause the heater to cycle on/off every 30-60 seconds and shows up as an HLS fault. I bought the manual bypass, new o-ring kit and the HLS (just in case - it was only $14 on Amazon) so for $54 I have a perfectly functional pool heater!

  • @synonyx
    @synonyx Год назад

    Thanks for the video! Might have to do this myself soon unfortunately.

  • @Easystreet208
    @Easystreet208 Год назад

    Just want to say thank you! My 250 was reading much cooler than it was

  • @Easystreet208
    @Easystreet208 Год назад

    What about a E01? I had mice in my box and I think they shorten out one of the red 240V converter wires.

    • @pvt-pilot
      @pvt-pilot Год назад

      E01 is "open thermistor". Check the thermistor connectors, wiring harness, and modular connector at the control board. If all is OK, you have a defective open thermistor that must be replaced.

    • @Easystreet208
      @Easystreet208 Год назад

      @@pvt-pilot so I replaced the thermister today and it seems to running normal but there is not the hot water coming out the jets like I am use to? Temp still shows like 44 and never climbs! No errors on display and heat light is on solid! There is hot exhaust coming out so not sure why it isn’t heating the water like it should! Any ideas? High temp sensor maybe?

    • @pvt-pilot
      @pvt-pilot Год назад

      @Torch-lt1ry If you have hot exhaust, then your igniter is working, your gas valve is working, and your burner is burning. Let's check for water leaking into your combustion chamber and filling it to the point of covering up some of the copper tubes inside. If this happens, the fire will not be able to engulf the tubes as necessary which will result in hot, moist exhaust with relatively cold output. There are about 12 vertically oriented bolts on you manifold (6 on each side). Remove either one of the bottom bolts on the manifold and see if water pours out. If water comes out, then you have a leaking heat coil assembly that will need to be replaced.

    • @Easystreet208
      @Easystreet208 Год назад

      @@pvt-pilot Thanks. They are 6 on each side like you said. 13mm. Do I need to have the system pressurized? Off of course but do not know if I need to have it pressurized or not?

    • @Easystreet208
      @Easystreet208 Год назад

      @@pvt-pilot unbolted bottom manifold bolt and no water! When I turn it on service heater light is on! Checked the bottom of the board and AFS light is lit red!

  • @ryandohrwardt1258
    @ryandohrwardt1258 Год назад

    Do you know how to change heater form Celsius to Fahrenheit?

    • @pvt-pilot
      @pvt-pilot Год назад

      I do not, sorry. Hopefully someone else on here knows how and can respond.

  • @MrFboccia
    @MrFboccia Год назад

    Great video. Maybe you can help me. I changed the control pad because i was nit able to raise or lower the temp on the older pad. The new pad gives me the same trouble.

    • @pvt-pilot
      @pvt-pilot Год назад

      Then you likely have an issue with the contol board. To prove this, you can disconnect the membrane pad and use needle nose pliers or a piece of wire to short the common pin #1 on your circuit board to the corresponding pin that traces out to the button you are pressing. I don't have the pins memorized, but I can do a membrane pad replacement video and illustrate this exact concept. (I hope to have that done in the next week or so) You just have to look at the back side of the membrane pad and follow each conductor embedded in the ribbon from the white modular connector to each respective button on the pad. Take note of this and short the common pin #1 on the control board to the temperature up button pin on the control board briefly and repeatedly to simulate pressing the button repeatedly. If you can't get the control board to respond this way, you have to replace the control board. If it does respond, then your new membrane pad is also defective. You can also use an ohm meter and connect it to your membrane pad across your temperature button female hole on the white connector of the membrane pad and the other lead on the common pin #1, then press the button on the pad and see if you get a 0 ohm short. This will prove your new membrane pad to be good or bad. You should see a short on each respective button if it is good.

  • @JonMoore-o9m
    @JonMoore-o9m Год назад

    I have a Mini Max pentair and only has an Err code. Nothing else? Heater will not come on. Was flashing 88.8 and I replaced the pressure switch and the temp sensor switch. Now the 88.8 is gone but just have the err code and still will not come on? Any suggestions?

    • @pvt-pilot
      @pvt-pilot Год назад

      Sorry, I'm just a home owner sharing knowledge gained from tinkering with my Mastertemp 400. I don't have any knowledge on your Mini Max. That said, 88.8 sounds like all possible pieces of each number on the display are illuminating, like what happens at a faulty gas station sign. I might start with the control board with that scenario, but really don't want to lead you in the wrong direction.

  • @Docinabox83
    @Docinabox83 Год назад

    I got an E01 message months ago, replaced the thermistor and it worked for 2-3 months. Again the E01 message is coming up, and I replaced the thermistor but it's still not working. Could something else be the problem with that message?

    • @pvt-pilot
      @pvt-pilot Год назад

      No, there are no secondary causes for E01. E01 means the contol board sees an open thermistor. The only causes for E01 would be corrosion on the thermistor pins of the control board or modular connector connected to the control board, chewed wiring harness, corrosion on the spade connectors at the thermistor or a defective, internally open thermistor. For testing, you might want to try putting an ohm meter on your thermistor before replacing it this time. If it is open, replace it again. When you turn on your heater, you should get "128" displayed and "R-#" whatever you revision number software, followed by a legitimate temperature reading. I had to replace mine 3 times in a row before I got one that was with pentair specs. Some of these cheap ones off eBay are trash.

    • @Docinabox83
      @Docinabox83 Год назад

      @@pvt-pilot thanks for the response. The thermistors worked fine when checked with the ohmeter. My FIL is a retired electrician. He was able to buy a replacement mother board and installed it. Working good as new again.

    • @pvt-pilot
      @pvt-pilot Год назад

      @@Docinabox83 Fantastic!

  • @DavidDrayer
    @DavidDrayer Год назад

    Can I use a mastertemp 400 in place of a mastertemp 250?

    • @pvt-pilot
      @pvt-pilot Год назад

      Yes, it will heat the water quicker at 400,000 BTU as opposed to 250,000 BTU heater