ElectroIG
ElectroIG
  • Видео 69
  • Просмотров 75 817

Видео

EnergyPQA.com® - How to Register Your User Account
Просмотров 194Год назад
EnergyPQA.com® - How to Register Your User Account
Introduction to Nexus® 1500+ Power Quality Meter and Basic Programming Steps
Просмотров 471Год назад
This video gives an overview of the Nexus® 1500 power quality meter and the CommunicatorPQA® application with some basic programming instructions.
Polling a Shark® Meter Using Modbus Protocol
Просмотров 263Год назад
Instructions for using a Shark® meter’s Modbus registers to poll the meter’s readings.
Installation of the Shark® 250 Meter
Просмотров 408Год назад
Instructions for installing the Shark® 250 power and energy meter, including mechanical installation, electrical installation, and wiring diagrams.
Installation of the MP200™ Metering System
Просмотров 204Год назад
Instructions for installing the MP200™ Metering System, including mechanical installation, electrical installation, and wiring diagrams.
Shark® 50B BACnet Communication
Просмотров 59Год назад
This video explains how to establish BACnet communication and download data using the Shark® 50B meter with native BACnet MS/TP.
MV90 Instructions Part 3: Shark® 270 Meter
Просмотров 130Год назад
This video continues the instructions for validating MV90 data from the Shark® 270 meter and explains how to investigate validation failures.
MV90 Instructions Part 2: Shark® 270 Meter
Просмотров 215Год назад
This video continues the instructions for accessing MV90 data from the Shark® 270 meter and explains how to verify imported data.
MV90 Instructions Part 1: Shark® 270 Meter
Просмотров 760Год назад
This video explains how to set up MV90 records for the Shark® 270 meter.
MP200™ Metering System in Enclosure Installation
Просмотров 105Год назад
This video explains how to install the MP200™ Metering System in NEMA 1 enclosure.
Shark® 270 Meter Advanced Programming with CommunicatorPQA® Software
Просмотров 82Год назад
This video explains detailed programming of the Shark® 270 meter’s Device Profile using CommunicatorPQA® software, including customizing the meter’s display screens.
Shark® 250 Meter Advanced Programming with CommunicatorPQA® Software
Просмотров 118Год назад
This video explains how to set up Transformer Line Loss and CT/PT compensation, power quality and alarms, historical logs, waveform recording, and email server and notification emails.
Shark® 270 Meter Basic Programming with CommunicatorPQA® Software
Просмотров 239Год назад
This video explains connecting to the Shark® 270 meter, viewing polling screens, and performing basic programming of the Shark® 270 meter’s Device Profile using CommunicatorPQA® software. It also explains the Ethernet option’s web server.
Shark® 250 Meter Device Profile Configuration Using CommunicatorPQA® Software
Просмотров 281Год назад
This video explains the Tools menu, and basic programming of the Device Profile. Disclaimer: Note that some of the screen captures are from an earlier software version but the functionality is the same.
Shark® 250 Meter Polling through CommunicatorPQA® Software
Просмотров 173Год назад
Shark® 250 Meter Polling through CommunicatorPQA® Software
Intro to Nexus® 1450 Power Quality Meter with Multiport Communication
Просмотров 110Год назад
Intro to Nexus® 1450 Power Quality Meter with Multiport Communication
Advanced Programming for the Nexus® 1450 Power Quality Meter with Multiport Communication
Просмотров 75Год назад
Advanced Programming for the Nexus® 1450 Power Quality Meter with Multiport Communication
Basic Programming for the Nexus® 1450 Power Quality Meter with Multiport Communication
Просмотров 383Год назад
Basic Programming for the Nexus® 1450 Power Quality Meter with Multiport Communication
MeterManagerPQA® Meter Data Management Software
Просмотров 1,3 тыс.2 года назад
MeterManagerPQA® Meter Data Management Software
CommunicatorPQA® Power Monitoring Software
Просмотров 1,5 тыс.2 года назад
CommunicatorPQA® Power Monitoring Software
Distributed Fault Recording Using Nexus® 1450 Meter and IEC 61850 GOOSE Messaging
Просмотров 2363 года назад
Distributed Fault Recording Using Nexus® 1450 Meter and IEC 61850 GOOSE Messaging
Shark 100/100S/200/200S/250/270 Multifunction Switchboard Power Meters - Programming
Просмотров 1,7 тыс.3 года назад
Shark 100/100S/200/200S/250/270 Multifunction Switchboard Power Meters - Programming
Nexus 1500+, 1450, 1252, and 1262/1272 Power Quality Meters - Programming Part 2
Просмотров 1 тыс.3 года назад
Nexus 1500 , 1450, 1252, and 1262/1272 Power Quality Meters - Programming Part 2
Nexus 1500+, 1450, 1252, and 1262/1272 Power Quality Meters - Programming Part 1
Просмотров 6753 года назад
Nexus 1500 , 1450, 1252, and 1262/1272 Power Quality Meters - Programming Part 1
EIG's ST40 Compact DIN Rail Energy Meter with Power Quality
Просмотров 3584 года назад
EIG's ST40 Compact DIN Rail Energy Meter with Power Quality
Overview of the Brand New ST40 Energy and Power Quality Meter Webinar
Просмотров 2854 года назад
Overview of the Brand New ST40 Energy and Power Quality Meter Webinar
SWB3 Switchboard Case for the Shark 270 Revenue Meter - How To Video
Просмотров 2884 года назад
SWB3 Switchboard Case for the Shark 270 Revenue Meter - How To Video
SWB3 Switchboard Case for the Nexus 1272/1262 Meter
Просмотров 6364 года назад
SWB3 Switchboard Case for the Nexus 1272/1262 Meter
ST40 Sneak Peek
Просмотров 1004 года назад
ST40 Sneak Peek

Комментарии

  • @imranafzal2126
    @imranafzal2126 6 месяцев назад

    very good explained ...but need one video how to test ...explanation good but need testing actual.

  • @jbferrer3
    @jbferrer3 9 месяцев назад

    Can I install the CT wires in the same conduit as the power?

    • @normanclarke1753
      @normanclarke1753 7 месяцев назад

      Yes. It is common to run voltage and current wires in the same conduit. It is not recommended to run communications cables ( Ethernet, RS485, RS232, etc.) in the same conduit as voltage and current wires.

    • @jbferrer3
      @jbferrer3 7 месяцев назад

      @@normanclarke1753 Thanks for the reply!

  • @Averam-u8z
    @Averam-u8z 10 месяцев назад

    Hi Thank you for sharing, will MV90 work if the recorder channels is set to secondary energy in interval

    • @normanclarke1753
      @normanclarke1753 7 месяцев назад

      MV-90 Secondary energy is supported in Nexus meters but is not supported in the Shark270 meter

    • @Averam-u8z
      @Averam-u8z 7 месяцев назад

      ​@@normanclarke1753Hi thanks a lot! Shark is an excellent meter. I hope secondary energy channels will be supported soon to extend our range of application.

  • @Autotrolingenieria
    @Autotrolingenieria 10 месяцев назад

    Is there any available tool in order to check if the PMU function is working properly in the nexus 1500+?

  • @fergg66
    @fergg66 11 месяцев назад

    If the shark-270 security is enabled it is required that the user and password are encrypted before the modbus write in the logging process. But in the energy meter documentation there is no information about what kind of encryption should be used. Any suggestions?

  • @nadanabil5694
    @nadanabil5694 11 месяцев назад

    How to make summation with genius energy meter , i want to take pulse output in genius and set pulse input in shark 270 energy meter how i do that plz ?!

  • @nadanabil5694
    @nadanabil5694 11 месяцев назад

    🎉

  • @montserratcortes3004
    @montserratcortes3004 Год назад

    Thank you very much for the information😃

  • @livingsafarillc
    @livingsafarillc Год назад

    have you connected a 200 via modbus to a Micrologix 1400?

  • @ZULFERISYAHPUTRA
    @ZULFERISYAHPUTRA 3 года назад

    Dear Sir.......................We have a Nexus 1252F type power meter, the current condition is not healthy because the communication is lost. How to reset it. Please provide a guide so that the power meter returns to normal. If you are willing to provide the software.

  • @ZULFERISYAHPUTRA
    @ZULFERISYAHPUTRA 3 года назад

    Dear Sir.......................We have a Nexus 1252F type power meter, the current condition is not healthy because the communication is lost. How to reset it. Please provide a guide so that the power meter returns to normal. If you are willing to provide the software.

  • @ZULFERISYAHPUTRA
    @ZULFERISYAHPUTRA 3 года назад

    Dear Sir.......................We have a Nexus 1252F type power meter, the current condition is not healthy because the communication is lost. How to reset it. Please provide a guide so that the power meter returns to normal. If you are willing to provide the software.

  • @ZULFERISYAHPUTRA
    @ZULFERISYAHPUTRA 3 года назад

    Dear Sir.......................We have a Nexus 1252F type power meter, the current condition is not healthy because the communication is lost. How to reset it. Please provide a guide so that the power meter returns to normal. If you are willing to provide the software.

    • @shabanashraf8582
      @shabanashraf8582 3 года назад

      Same problem with us Nexus 1500 Plz Suggest Solution

  • @phillipcramer7936
    @phillipcramer7936 4 года назад

    I don't see the link on your website to download the free version of the Communicator EXT 4.0 software that you speak about in this video.

  • @avelinogoncalves7217
    @avelinogoncalves7217 4 года назад

    Amazing devices! Love mine!!!

  • @BudiSetiawan-vd6hm
    @BudiSetiawan-vd6hm 4 года назад

    Hai support, on shark 100 display, what is the meaning of letter A, B, C If A = Tot B = 0013 C = 5678 Pulse Wh, and Mega count Thanks

    • @ElectroIG
      @ElectroIG 4 года назад

      Hi Budi, The display is showing the Total Watt Hour = 135,678 MWh

  • @ateeqkhan09
    @ateeqkhan09 4 года назад

    Please upload the nexus webinar that was arranged on 29 April 2020

    • @ElectroIG
      @ElectroIG 4 года назад

      You can find that webinar recording here: ruclips.net/video/s89pGzxeULk/видео.html

  • @osamaalhurani4591
    @osamaalhurani4591 4 года назад

    Thanks you, we need guide for DNP3.0

    • @ElectroIG
      @ElectroIG 4 года назад

      Hi Osama, Coming soon! Check back on Thursday & Friday to see our DNP3 videos.

  • @onsiteservices7581
    @onsiteservices7581 5 лет назад

    This type of meters are really a high tech meter device......i have a couple of Nexus units for doing reliable and accuracy power quality studies and.................... the performance is excellent. I reccomend to trust on this brand for using the devices on any electrical measurement application.

  • @knoxewers3766
    @knoxewers3766 5 лет назад

    you say repeatedly "contact me..." but provide no contact information. You mention the meter can operate on 18 - 60 volt dc or 90 - 265 volt ac or dc but you give no information how to configure for the different voltage inputs. WTF????

  • @ICgasm
    @ICgasm 6 лет назад

    Pro tip, put your script in front of the camera and not to the right.

  • @Sam-gb2hq
    @Sam-gb2hq 6 лет назад

    Great meters, we are upgrading a lot of our distribution metering over to these.

    • @rebeccacrysdale9852
      @rebeccacrysdale9852 6 лет назад

      how is it going? do you like it? I like the fact you can measure two feeds at once.